background image

1.WHAT IS SUPPLIED?

Standard upon delivery of 

VAC-CB-UR-AIRPICK-

KITX

2.TOOLS YOU NEED

4.MOUNTING

3.GET THE LATEST

THANK YOU FOR 

CHOOSING ROBOTIQ

4 mm 

Hex Key

1. Mount the coupling on your robot arm. Align with the 

provided dowel pin.

2. Secure by inserting the M6 screws and tooth lock washers.
3. Mount the Vacuum Gripper on the coupling. 

Align with the dowel pin.

4. Secure by inserting the M5 screws and tooth lock washers.
5. Plug the device cable into the coupling pigtail and attach 

the cable along the robot arm using a cable routing system.

6. To install the 2 or 4 suction cups kits for gripper, please 

refer to the 

Connector Assembly Guide

. You can find in 

this guide details on assembling the Suction Cup System.

BEFORE OPERATING THE GRIPPER, PLEASE 

READ THE INSTRUCTION MANUAL.

This step-by-step guide will allow you to 

install

 and 

use your

 

AIRPick Vacuum Gripper

 on CB Series 

Universal Robots.

• 

Vacuum generator.......................(

VAC-GRP-AIRPICK

)

• 

Gripper coupling...............................(GRP-CPL-062)

• 

USB to RS485 Adapter..........(ACC-ADT-USB-RS485)

• High-flex device cable.........(CBL-COM-2065-10-HF)

• Suction Cup Option

   

KIT1

...................................................(1 

SUCTION

 

CUP

)

   

KIT2

.................................................(

SUCTION

 

CUPS

)

   

KIT4

.................................................(

SUCTION

 

CUPS

)

• 

Required hardware

Visit

:

 

support.robotiq.com

D

OWNLOADING

 

THE

 URCAP

1. 

Select brand > Universal Robots > Vacuum Grippers 

> Software > Gripper Software.

2. Select 

DOWNLOAD ZIP

.

3. Save the ZIP file 

UCG-X.X.X 

to a USB stick.

5.WIRING

1. Connect the red wire to a 24V pin.
2. Connect the black wire to a 0V pin.

3. Connect the communication wires in the USB converter 

(ACC-ADT-USB-RS485) as shown. 

4. Connect the USB converter to the UR controller.

485+

485-

485 GND

(1)

(2)

(3)

1

2

3

4

5

WHITE

Pin

Signal Name

1

2

485 + (A)

SHIELD

CBL-COM-2065-10-HF

High-Flex Device Cable

GREEN

3

485 GND

485 - (B)

Power

PWR

GND

24V

0V

24V

CI0

24V

CI1

CI3

24V

CI2

24V

CI

24V

CI4

24V

CI5

CI7

24V

CI6

24V

CI

0V

CO0

0V

CO1

CO3

0V

CO2

0V

CO

0V

CO4

0V

CO5

CO7

0V

CO6

0V

CO

    

The red (24V) and black (0V) wires of the device cable  

(CBL-COM-2065-10-HF) provide power to the Gripper. 

C

ONNECTING

 

THE

 A

IR

 S

UPPLY

1. Insert the 8 mm flexible tube in the air supply port.
2. Once the tube inserted, make sure the safety clip is 
present to secure the tube.
3. 

Route the air tube along the robot arm using a cable 

routing system.

• Recommended air pressure  = 7 bar [101.5 psi]

   Maximum = 7 bar [101.5 psi] 

• Dry and filtered air only; 

   Follow ISO 8573-1, class 3.4.3 Standard.

• Use of a local pressure regulator with a filter 

   and air dryer is recommended.

LEAVE ENOUGH EXCESS CABLE TO ALLOW 

FULL ROBOT MOVEMENT.

(M5 screws and

washers)

(M6 screws and

washers)

(vacuum generator)

(gripper coupling)

(coupling pigtail)

(dowel pin)

(suction cup)

(hand tightened)

2mm 

slotted screwdriver

(not included)

CAREFUL ! 

FRAGILE PINS

(device cable)

Reviews: