![Ronde & Schwarz 1304.0004K03 Скачать руководство пользователя страница 730](http://html1.mh-extra.com/html/ronde-and-schwarz/1304-0004k03/1304-0004k03_user-manual_1484987730.webp)
Remote Commands
R&S
®
FPL1000
730
User Manual 1178.3370.02 ─ 11
<RBW>
Defines the resolution bandwidth for a list entry.
<VBW>
Defines the measurement time for a list entry.
<MeasTime>
Defines the measurement time for a list entry.
Range:
1 µs to 16000 s
Default unit: s
<TriggerLevel>
Reserved for future use; currently: must be 0.
Example:
See
Chapter 10.6.15.2, "Example: Performing List Evaluation"
[SENSe:]LIST:POWer:SET
<State>, <State>, <State>, <TriggerSource>,
<TriggerSlope>, <TriggerOffset>, <GateLength>
This command defines global List Evaluation parameters.
These parameters are valid for every frequency you want to measure.
The state of the first three parameters (<PeakPower>, <RMSPower> and <AVG-
Power>) define the number of results for each frequency in the list.
Note that you have to set the trigger level
after
sending this command.
Parameters:
<State>
ON | OFF | 0 | 1
Turns peak power evaluation on and off.
*RST:
1
<State>
ON | OFF | 0 | 1
Turns RMS power evaluation on and off.
*RST:
0
<State>
ON | OFF | 0 | 1
Turns average power evaluation on and off.
*RST:
0
<TriggerSource>
IMMediate | LINE | EXTernal | VIDeo | RFPower | IFPower |
RFPower | EXT2 | EXT3 | EXT4 | LXI | EXTernal | IMMediate |
IFPower | RFPower | VIDeo
Selects a trigger source.
<TriggerSlope>
POSitive | NEGative
Selects the trigger slop.
<TriggerOffset>
Defines the trigger delay.
Range:
negative measurement time to 30 s
*RST:
0
Default unit: s
Configuring and Performing Measurements