![Ronde & Schwarz 1304.0004K03 Скачать руководство пользователя страница 769](http://html1.mh-extra.com/html/ronde-and-schwarz/1304-0004k03/1304-0004k03_user-manual_1484987769.webp)
Remote Commands
R&S
®
FPL1000
769
User Manual 1178.3370.02 ─ 11
ON | 1
Switches the function on
*RST:
0
Example:
INP:GAIN:STAT ON
Switches on 20 dB preamplification.
Manual operation:
See
10.8.3.4
Scaling the Y-Axis
DISPlay[:WINDow<n>]:TRACe<t>:Y[:SCALe]
................................................................... 769
DISPlay[:WINDow<n>]:TRACe<t>:Y[:SCALe]:AUTO ONCE
............................................... 769
DISPlay[:WINDow<n>][:SUBWindow<w>]:TRACe<t>:Y[:SCALe]:MODE
..............................769
DISPlay[:WINDow<n>]:TRACe<t>:Y[:SCALe]:RPOSition
................................................... 770
DISPlay[:WINDow<n>][:SUBWindow<w>]:TRACe<t>:Y:SPACing
........................................770
DISPlay[:WINDow<n>]:TRACe<t>:Y[:SCALe]
<Range>
This command defines the display range of the y-axis (for all traces).
Note that the command works only for a logarithmic scaling. You can select the scaling
with
DISPlay[:WINDow<n>][:SUBWindow<w>]:TRACe<t>:Y:SPACing
.
Suffix:
<n>
.
<t>
irrelevant
Parameters:
<Range>
Range:
1 dB to 200 dB
*RST:
100 dB
Default unit: HZ
Example:
DISP:TRAC:Y 110dB
Manual operation:
See
DISPlay[:WINDow<n>]:TRACe<t>:Y[:SCALe]:AUTO ONCE
Automatic scaling of the y-axis is performed once, then switched off again (for all
traces).
Suffix:
<n>
.
<t>
irrelevant
Manual operation:
See
DISPlay[:WINDow<n>][:SUBWindow<w>]:TRACe<t>:Y[:SCALe]:MODE
<Mode>
This command selects the type of scaling of the y-axis (for all traces).
Setting Basic Spectrum RF Measurement Parameters