Remote Commands
R&S
®
FPL1000
870
User Manual 1178.3370.02 ─ 11
Suffix:
<n>
.
<m>
Return values:
<PhaseNoise>
numeric value
The difference between the measured carrier power and the
noise power at the position of the specified (normal) marker.
Example:
CALC:MARK2:FUNC:PNO:RES?
Outputs the result of phase-noise measurement of the marker 2.
Usage:
Query only
CALCulate<n>:MARKer<m>:FUNCtion:PNOise[:STATe]
<State>
This command turns the phase noise measurement at the marker position on and off.
Suffix:
<n>
.
<m>
Parameters:
<State>
ON | OFF | 0 | 1
OFF | 0
Switches the function off
ON | 1
Switches the function on
Example:
CALC:MARK2:FUNC:PNO ON
Switches on the phase-noise measurement for the marker 2.
10.8.8.11
Band Power Marker
The following commands control the marker for band power measurements.
Using Markers
CALCulate<n>:MARKer<m>:FUNCtion:BPOWer:AOFF
..................................................... 870
CALCulate<n>:MARKer<m>:FUNCtion:BPOWer:MODE
.................................................... 871
CALCulate<n>:MARKer<m>:FUNCtion:BPOWer:RESult?
..................................................871
CALCulate<n>:MARKer<m>:FUNCtion:BPOWer:SPAN
..................................................... 872
CALCulate<n>:MARKer<m>:FUNCtion:BPOWer[:STATe]
...................................................872
CALCulate<n>:MARKer<m>:FUNCtion:BPOWer:AOFF
Removes all band power markers in the specified window.
Suffix:
<n>
.
<m>
irrelevant
Setting Basic Spectrum RF Measurement Parameters