![Ronde & Schwarz 1304.0004K03 Скачать руководство пользователя страница 161](http://html1.mh-extra.com/html/ronde-and-schwarz/1304-0004k03/1304-0004k03_user-manual_1484987161.webp)
The Spectrum Application (RF Measurements)
R&S
®
FPL1000
161
User Manual 1178.3370.02 ─ 11
Example:
For example, in
, "31 <
P <
39" is indicated as the used power class is
defined from 31 to 39.
Figure 6-25: Spectrum Emission Mask result displays
In addition to the graphical results of the SEM measurement displayed in the diagram,
a result summary is displayed to evaluate the limit check results (see also
The following information is provided in the result summary:
Label
Description
General information
"Standard"
Loaded standard settings
"Tx Power"
Power of the reference range
"Tx Bandwidth"
Tx bandwidth used by the reference range
"RBW"
RBW used by the reference range
Range results
"Range Low"
Start of the frequency range the peak value was found in
"Range Up"
Frequency range end the peak value was found in
"RBW"
RBW of the range
"Frequency"
Frequency of the peak power level
"Power Abs"
Absolute peak power level within the range
Measurements and Results