Element
Description
Version
Options
- V2cIP
IP address of the
SNMP management station for the
corresponding version
SNMPv2
- V3IP
IP address of the
SNMP management station for the
corresponding version
SNMPv3
20.9.2 Activation
Once the configuration file has been adapted, rename it to
server.site.snmp.SNMPMappings.default.xml and upload it via the Customizer login. Afterwards the
Observer server or at least the NETAVIS services have to be restarted for the SNMP agent to be
activated.
To receive the SNMP data sent by Observer a so-called SNMP management station software is needed.
20.9.3 Available system information and Observer events
The following system information and Observer events are available via SNMP:
System information
(available with SNMP Get / Walk via the NETAVIS-MIB):
NETAVIS-MIB Name
Description
Host Table Entry
o2HostID
Unique identifier of the server.
o2HostName
Human readable name of the server.
o2HostOSNameAndVersion
Name and version of the Operating System running on the server.
o2HostCPUIdle
Percent of CPU idle time (the higher this value means the less work
the CPU is doing).
o2HostTotalMemory
Size of the RAM in kBytes.
o2HostUsedMemory
Total number of RAM kBytes in use.
o2HostTotalSwap
Number of configured kBytes of swap space.
o2HostUsedSwap
Number of used kBytes of swap space.
o2HostUptime
The time (in UNIX seconds) since the NETAVIS server has been
booted.
Storage Table Entry
o2StorageHostID
Unique identifier of the server where this disk is connected to.
o2StorageID
Identifier which is valid only locally on the server.
o2StoragePath
For internal storage types it shows the device path of the partition
where the storage is located (e.g. /dev/sda1). For external storage
types it shows the mount point or directory where the external
device has been mounted.
o2StorageTotal
Total number of MBytes.