NETAVIS Observer 4.6 User Manual (October 2015)
Page 172 of 204
Administration
on page 168). Then you can choose any of its input ports or relays and define
whether the port value changing from
0->1
,
1->0
or
Any
value change is used as the trigger.
e.
Number plate detected
: In its basic configuration the trigger is simply a number plate being
detected on one or multiple cameras and/or camera groups which can be selected.
Additionally it is also possible to limit the trigger to only occur when a number plate
is in
or
is
not in
one or multiple NPR lists (see
18 NPR List Management
on page 175).
f.
Object crossed field or tripwire
: In its basic configuration the trigger is any object is
crossing field and object crosses tripwire iCAT detection (option:
Any definition
) on one or
multiple cameras and/or camera groups which can be selected. Additionally it is also possible
to limit the trigger to only occur when any of the selected iCAT Object is Crossing Field and
Object Crosses Tripwire events occurs (option:
Any selected definition
). When selecting
more than one camera then only the subset of identically named iCAT Object is Crossing Field
and Object Crosses Tripwire definitions available on all cameras is shown here.
g.
Object started moving in field
: In its basic configuration the trigger is any object starts
moving in field iCAT detection (option:
Any definition
) on one or multiple cameras and/or
camera groups which can be selected. Additionally it is also possible to limit the trigger to only
occur when any of the selected iCAT Object Starts Moving in Field events occurs (option:
Any
selected definition
). When selecting more than one camera then only the subset of
identically named iCAT Object Starts Moving in Field definitions available on all cameras is
shown here.
h.
Object stopped in field
: In its basic configuration the trigger is any object stops in field
iCAT detection (option:
Any definition
) on one or multiple cameras and/or camera groups
which can be selected. Additionally it is also possible to limit the trigger to only occur when
any of the selected iCAT Object Stops in Field events occurs (option:
Any selected
definition
). When selecting more than one camera then only the subset of identically named
iCAT Object Stops in Field definitions available on all cameras is shown here.
6.
By clicking on the
Add action
button you can then add one or multiple actions which will be
executed when the trigger configured above occurs. NETAVIS Observer 4.6 currently supports the
following actions:
a.
Enable current continuous recording scheduling
: You can select for which
Camera(s)
the current continuous recording scheduling will be enabled: either the
camera from the
event
which triggered the rule or any other camera(s).
Note
: This action does not automatically start a continuous recording on the corresponding
camera(s)! Rather it simply enables a previously configured continuous recording schedule
(see
7.1 Programming archive recordings
on page 71) which is scheduled to run at the current
time. Changes of the scheduling can take up to 2 seconds to be executed and no other
changes should be made during that time.
b.
Disable current continuous recording scheduling
: You can select for which
Camera(s)
the current continuous recording scheduling will be disabled: either the
camera from the
event
which triggered the rule or any other camera(s).
Note
: This action does not automatically stop a continuous recording on the corresponding
camera(s)! Rather it simply disables a previously configured continuous recording schedule
(see
7.1 Programming archive recordings
on page 71) which is scheduled to run at the current
time. Changes of the scheduling can take up to 2 seconds to be executed and no other
changes should be made during that time.