15. MR-J3W-0303BN6 SERVO AMPLIFIER
15 - 43
15.5.4 Other function parameters (No.PF
)
POINT
Each parameter name of Other function parameters (No.PF
) are displayed as
manufacturer settings in the parameter setting window of MR Configurator and MR
Configurator2. However, you can set parameter No.PF06 and PF12. The other
parameters are for manufacturer. Do not change them.
No.
Symbol
Name and function
Each/
common
Default
value
Unit
Setting
range
PF06 *FOP5 Function selection F-5
Electronic dynamic brake selection
Electronic dynamic brake selection
0: Automatic setting
2: Disabled
Set Electronic dynamic brake operating time with
parameter No.PF12 (DBT).
Setting "0" enables the electronic dynamic brake.
0
0
0
Each 0000h Refer
to
Name
and
function
column.
PF12
DBT
Electronic dynamic brake operating time
Set a operating time for the electronic dynamic brake.
Communication with the controller cannot be made during the electronic dynamic
brake operation due to SSCNET communication brake.
When reconnecting servo amplifier to the communication, be sure to perform after
the setting value of the electronic dynamic brake operating time has passed and
after checking that the motor has stopped.
Each 100 ms 0
to
10000
15.5.5 Option setting parameters (No.Po
)
POINT
Each parameter name of Option setting parameters (No.Po
) are displayed as
manufacturer settings in the parameter setting window of MR Configurator and MR
Configurator2. However, you can set parameter No.Po04. The other parameters
are for manufacturer. Do not change them.
No.
Symbol
Name and function
Each/
common
Default
value
Unit
Setting
range
Po04 **OOP
2
Function selection O-2
0
0
HG-AK servo motor main circuit power supply selection
0: 48VDC selection
1: 24VDC selection
Select a voltage to connect to the main circuit power supply
for connecting a HG-AK servo motor.
When using a HG-AK servo motor with 24VDC, set the
parameter to "1 ".
Overvoltage (33.1) will occur if "1 " is set and used with
48VDC.
0
Common 0000h
Refer to
Name
and
function
column.
Содержание MELSERVO-J3W Series
Страница 17: ...8 MEMO ...
Страница 27: ...1 FUNCTIONS AND CONFIGURATION 1 10 MEMO ...
Страница 87: ...4 STARTUP 4 14 MEMO ...
Страница 117: ...5 PARAMETERS 5 30 MEMO ...
Страница 129: ...6 GENERAL GAIN ADJUSTMENT 6 12 MEMO ...
Страница 185: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 241: ...11 OPTIONS AND AUXILIARY EQUIPMENT 11 56 MEMO ...
Страница 274: ...13 USING A LINEAR SERVO MOTOR 13 25 1 2 3 4 ...