5. PARAMETERS
5 - 5
5.1.5 Using absolute position detection system
Parameter
No. Symbol
Name
Setting
Factory
setting
Unit
Setting
range
PA03 *ABS Absolute
position detection system
Each axis
0000h
Refer to
the text.
POINT
Turn off the power and then on again, or reset the controller after setting the
parameter to validate the parameter value.
This parameter cannot be used in the speed control mode.
Set this parameter when using the absolute position detection system in the position control mode.
Selection of absolute position detection system (refer to chapter 12)
0: Used in incremental system
1: Used in absolute position detection system
Parameter No.PA03
0 0 0
5.1.6 Forced stop input selection
Parameter
No. Symbol
Name
Setting
Factory
setting
Unit
Setting
range
PA04 *AOP1 Function selection A-1
Common
0000h
Refer to
the text.
POINT
Turn off the power and then on again, or reset the controller after setting the
parameter to validate the parameter value.
The servo forced stop function is avoidable.
Selection of servo forced stop
0: Valid (Forced stop (EM1) is used.)
1: Invalid (Forced stop (EM1) is not used.)
Parameter No.PA04
0
0
0
When not using the forced stop (EM1) of servo amplifier, set the selection of servo forced stop to Invalid ( 1
). At this time, the forced stop (EM1) automatically turns on inside the servo amplifier.
Содержание MELSERVO-J3W Series
Страница 17: ...8 MEMO ...
Страница 27: ...1 FUNCTIONS AND CONFIGURATION 1 10 MEMO ...
Страница 87: ...4 STARTUP 4 14 MEMO ...
Страница 117: ...5 PARAMETERS 5 30 MEMO ...
Страница 129: ...6 GENERAL GAIN ADJUSTMENT 6 12 MEMO ...
Страница 185: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 241: ...11 OPTIONS AND AUXILIARY EQUIPMENT 11 56 MEMO ...
Страница 274: ...13 USING A LINEAR SERVO MOTOR 13 25 1 2 3 4 ...