APPENDIX
App. - 3
Parameter
No.
Name Setting
Difference
from MR-J3-B
Comment
PC22 to
PC26
This parameter is not used.
PC27
Function selection C-9
Each axis
None
PC28 to
PC32
This parameter is not used.
Parameter
No.
Name Setting
Difference
from MR-J3-B
Comment
PD01
This parameter is not used.
None
PD02
Input signal automatic ON selection
Each axis Function added Automatically ON function for FLS and RLS is added.
PD03 to
PD06
This parameter is not used.
None
PD07
Output signal device selection 1
(A-axis: CN3-12 B-axis: CN3-25)
Each axis
Specification
change
Connector pin numbers are changed for MR-J3W.
PD08
This parameter is not used.
Specification
change
Cannot be assigned to MR-J3W-B.
PD09
Output signal device selection 3
(A-axis: CN3-11 B-axis: CN3-24)
Each axis
Specification
change
Connector pin numbers are changed for MR-J3W.
PD10 to
PD13
This parameter is not used.
PD14
Function selection D-3
Each axis
None
PD15 to
PD32
This parameter is not used.
Parameter
No.
Name Setting
Difference
from MR-J3-B
Comment
PF06
Function selection F-5
Each axis New addition
PF12
Electronic dynamic brake operating time
Each axis New addition
Used for MR-J3W-0303BN6 servo amplifier.
Parameter
No.
Name Setting
Difference
from MR-J3-B
Comment
PS01
Linear function selection 1
Each axis Function added
PS02
Linear encoder resolution setting
Numerator
Each axis Function added
PS03
Linear encoder resolution setting
Denominator
Each axis Function added
PS04
Linear function selection 2
Each axis Function added
PS05
Linear servo motor control position
deviation error detection level
Each axis Function added
PS06
Linear servo motor control speed
deviation error detection level
Each axis Function added
PS07
Linear servo motor control thrust deviation
error detection level
Each axis Function added
PS08
Linear function selection 3
Each axis Function added
PS09
Magnetic pole detection voltage level
Each axis Function added
Not used for rotary servo motors. Used for linear
servo motors. (Factory setting does not need to be
changed.)
PS10 to
PS16
This parameter is not used.
None
PS17
Minute position detection method function
selection
Each axis Function added
PS18
Minute position detection method
identification signal amplitude
Each axis Function added
Not used for rotary servo motors. Used for linear
servo motors.
PS19 to
PS32
This parameter is not used.
None
Содержание MELSERVO-J3W Series
Страница 17: ...8 MEMO ...
Страница 27: ...1 FUNCTIONS AND CONFIGURATION 1 10 MEMO ...
Страница 87: ...4 STARTUP 4 14 MEMO ...
Страница 117: ...5 PARAMETERS 5 30 MEMO ...
Страница 129: ...6 GENERAL GAIN ADJUSTMENT 6 12 MEMO ...
Страница 185: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 241: ...11 OPTIONS AND AUXILIARY EQUIPMENT 11 56 MEMO ...
Страница 274: ...13 USING A LINEAR SERVO MOTOR 13 25 1 2 3 4 ...