13. USING A LINEAR SERVO MOTOR
13 - 44
(2) List of details
No.
Symbol
Name and function
Setting
Factory
setting
Unit
Setting
range
PB06
GD2
Load to mass of the linear servo motor primary side (coil) ratio
Used to set the load mass ratio to the mass of the linear servo motor primary
side (coil).
When auto tuning mode 1 and interpolation mode are selected, the result of
auto tuning is automatically used. In this case, it varies between 0.0 and 100.0.
When parameter No.PA08 is set to "
2" or "
3", this parameter can
be set manually.
Each
axis
7.0 Multi-
plier
( 1)
0.0
to
300.0
PB29 GD2B Gain changing - load to mass of the linear servo motor primary side (coil) ratio
Used to set the load to mass of the linear servo motor primary side (coil) ratio
when gain changing is valid.
This parameter is made valid when the auto tuning is invalid (parameter
No.PA08:
3).
Each
axis
7.0 Multi-
plier
( 1)
0.0
to
300.0