13. USING A LINEAR SERVO MOTOR
13 - 70
Alarm No.30
Name: Regenerative error
Stop method: All axes stop
Alarm description
Permissible regenerative power of the built-in regenerative resistor or regenerative option is exceeded.
Regenerative transistor in the servo amplifier is faulty.
Display Name
Cause
Checkpoint
Finding
Action
30.1 Regeneration
heat error
Same as for the rotary servo motor.
Refer to section 8.3.
30.2 Regenerative
transistor error
30.3 Regenerative
transistor
feedback data
error
Alarm No.31
Name: Overspeed
Stop method: Corresponding axis stops
Alarm description
Linear servo motor speed exceeds the instantaneous permissible speed.
Display Name
Cause
Checkpoint
Finding
Action
31.1 Abnormal
motor
speed
Same as for the rotary servo motor.
Refer to section 8.3.
Alarm No.32
Name: Overcurrent
Stop method: All axes stop
Alarm description
Current that flew is the permissible current of the servo amplifier or higher.
Display Name
Cause
Checkpoint
Finding
Action
32.1 Overcurrent
detected at
hardware
detection circuit
(during
operation).
Same as for the rotary servo motor.
Refer to section 8.3.
32.2 Overcurrent
detected at
software
detection function
(during
operation).
32.3 Overcurrent
detected at
hardware
detection circuit
(during a stop).
32.4 Overcurrent
detected at
software
detection function
(during a stop).
Alarm No.33
Name: Overvoltage
Stop method: All axes stop
Alarm description
Bus voltage exceeds 400VDC.
Display Name
Cause
Checkpoint
Finding
Action
33.1 Main
circuit
voltage error
Same as for the rotary servo motor.
Refer to section 8.3.
Содержание MELSERVO-J3W Series
Страница 17: ...8 MEMO ...
Страница 27: ...1 FUNCTIONS AND CONFIGURATION 1 10 MEMO ...
Страница 87: ...4 STARTUP 4 14 MEMO ...
Страница 117: ...5 PARAMETERS 5 30 MEMO ...
Страница 129: ...6 GENERAL GAIN ADJUSTMENT 6 12 MEMO ...
Страница 185: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 241: ...11 OPTIONS AND AUXILIARY EQUIPMENT 11 56 MEMO ...
Страница 274: ...13 USING A LINEAR SERVO MOTOR 13 25 1 2 3 4 ...