14. USING A DIRECT DRIVE MOTOR
14 - 45
Alarm No.: 16
Name: Encoder initial communication error 1
Stop system: Each axis
Alarm content
An error occurred in the communication between the encoder and the servo amplifier.
Display
Detail name
Cause
Check method
Check result
Action
16.1 Encoder
receive data
error 1
16.2 Encoder
receive data
error 2
16.3 Encoder
receive data
error 3
Same as for the rotary servo motors.
Refer to section 8.3.
16.5 Encoder
transmission
data error 1
16.6 Encoder
transmission
data error 2
16.7 Encoder
transmission
data error 3
Alarm No.: 17
Name: Board error
Stop system: All axes
Alarm content
A part in the servo amplifier is failure
Display
Detail name
Cause
Check method
Check result
Action
17.1 AD
converter
error
17.2 Current
feedback data
error
17.3 Custom IC error
17.4 Amplifier
detection signal
error
17.5 Rotary
switch
error
17.6 DIP switch error
Same as for the rotary servo motors.
Refer to section 8.3.
Alarm No.: 19
Name: Memory error 3 (Flash-ROM)
Stop system: All axes
Alarm content
A part (Flash-ROM) in the servo amplifier is failure.
Display
Detail name
Cause
Check method
Check result
Action
19.1 Flash-ROM
error 1
19.2 Flash-ROM
error 2
Same as for the rotary servo motors.
Refer to section 8.3.
Содержание MELSERVO-J3W Series
Страница 17: ...8 MEMO ...
Страница 27: ...1 FUNCTIONS AND CONFIGURATION 1 10 MEMO ...
Страница 87: ...4 STARTUP 4 14 MEMO ...
Страница 117: ...5 PARAMETERS 5 30 MEMO ...
Страница 129: ...6 GENERAL GAIN ADJUSTMENT 6 12 MEMO ...
Страница 185: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 241: ...11 OPTIONS AND AUXILIARY EQUIPMENT 11 56 MEMO ...
Страница 274: ...13 USING A LINEAR SERVO MOTOR 13 25 1 2 3 4 ...