4. STARTUP
4 - 8
(2) Indication list
Indication Status
Description
A b
Initializing
Power of the servo amplifier was switched on at the condition that the power of
servo system controller is OFF.
The axis No. set to the servo system controller does not match the axis No. set
with the rotary axis setting switch (SW1) of the servo amplifier.
A servo amplifier fault, or communication error with the servo system controller or
the prior servo amplifier axis occured. In this case, the indication changes as
follows:
"Ab " "AC " "Ad " "Ab "
The servo system controller is faulty.
.
A b
Initializing
During initial setting for communication specifications
A C
Initializing
Initial setting for communication specifications completed, and then it synchronized
with servo system controller.
A d
Initializing
During initial parameter setting communication with servo system controller
A E
Initializing
During motor encoder information and telecommunication with servo system
controller
A F
Initializing
During initial signal data communication with servo system controller
A H
Initializing completion
During the completion process for initial data communication with servo system
controller
A A
Initializing standby
The power supply of servo system controller is turned off during the power supply of
servo amplifier is on.
(Note 1) b # # Ready OFF
The ready off signal from the servo system controller was received.
(Note 1) d # # Servo ON
The ready off signal from the servo system controller was received.
(Note 1) C # # Servo OFF
The ready off signal from the servo system controller was received.
(Note 2)
Alarm Warning
The alarm No./warning No. that occurred is displayed. (Refer to section 8.1.)
8 8
8
CPU Error
CPU watchdog error has occurred.
(Note 3)
0 A.
b
0 b.
b
JOG operation, positioning operation, program operation, DO forced output.
(Note 1)
# #.
b
# #.
d
# #.
C
(Note 3)
Test operation mode
Motor-less operation
Note 1. ## denotes any of numerals 00 to 16 and what it means is listed below.
# Description
0A/0B
Set to the test operation mode.
1 First
axis
2 Second
axis
3 Third
axis
4 Fourth
axis
5 Fifth
axis
6 Sixth
axis
7 Seventh
axis
8 Eighth
axis
9 Ninth
axis
10 Tenth
axis
11 Eleventh
axis
12 Twelfth
axis
13 Thirteenth
axis
14 Fourteenth
axis
15 Fifteenth
axis
16 Sixteenth
axis
2. ** indicates the warning/alarm No. "A" in the third digit indicates the A-axis, and the "B" indicates the B-axis.
3. Requires the MR Configurator.
Содержание MELSERVO-J3W Series
Страница 17: ...8 MEMO ...
Страница 27: ...1 FUNCTIONS AND CONFIGURATION 1 10 MEMO ...
Страница 87: ...4 STARTUP 4 14 MEMO ...
Страница 117: ...5 PARAMETERS 5 30 MEMO ...
Страница 129: ...6 GENERAL GAIN ADJUSTMENT 6 12 MEMO ...
Страница 185: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 241: ...11 OPTIONS AND AUXILIARY EQUIPMENT 11 56 MEMO ...
Страница 274: ...13 USING A LINEAR SERVO MOTOR 13 25 1 2 3 4 ...