4. STARTUP
4 - 13
(b) Alarms
The following alarms and warning do not occur. However, the other alarms and warnings occur as when
the servo motor is connected.
Encoder initial communication error 1 (16. )
Encoder normal communication error 1 (20. )
Encoder normal communication error 2 (21. )
Absolute position erase (25. )
Battery cable disconnection warning (92.1)
Battery warning (9F.1)
Main circuit off warning (E9. )
(2) Operating procedure
1) Switch off servo amplifier
2) Set parameter No.PC05 to "1", change test operation mode switch (SW2-1) to normal condition side
"Down", and then turn on the power supply.
C
B
7
9
6
8
5
4
3
2
1
0
F
E
D
A
1
2
ON 4E
SW1
SW2
TEST
SW2
DOWN
UP
1
2
Set SW2-1 to "DOWN"
3) Perform motor-less operation with the personal computer.
The display shows the following screen.
Decimal point flickers.