11. OPTIONS AND AUXILIARY EQUIPMENT
11 - 38
(2) Wires for cables
When fabricating a cable, use the wire models given in the following table or equivalent.
Table 11.2 Wires for option cables
Characteristics of one core
Type Model
Length
[m]
Core size
[mm
2
]
Number
of Cores Structure
[Wires/mm]
Conductor
resistance
[ /mm]
Insulation
coating
OD d [mm]
(Note 1)
(Note 2)
Finishing
OD [mm]
Wire model
MR-J3ENCBL_M-A1-L
MR-J3ENCBL_M-A2-L
2 to 10
AWG22
6
(3 pairs)
7/0.26
53 or
less
1.18 7.1
(Note 3)
VSVP 7/0.26 (AWG#22 or
equivalent)-3P
KB-1655-2 (Bando Densen)
MR-J3ENCBL_M-A1-H
MR-J3ENCBL_M-A2-H
2 to 10
AWG22
6
(3 pairs)
70/0.08
56 or
less
1.17 7.1
(Note 3)
TPE SVP 70/0.08 (AWG#22 or
equivalent)-3P
KB-2237-2 (Bando Densen)
MR-J3JCBL03M-A1-L
MR-J3JCBL03M-A2-L
0.3 AWG26
8
(4 pairs)
30/0.08
233 or
less
1.2 7.1 0.3
T/2464-1061/IIA-SB 4P×26AWG
(Taiyo Cabletec)
AWG28
4
(2 pairs)
7/0.127
232 or
less
1.18
2 to 10
AWG22 2 17/0.16
28.7 or
less
1.50
7.0
(Note 3)
20276 composite 6-core shielded
cable
Ban-gi-shi-16395-1 (Bando
Densen)
MR-EKCBL_M-L
20 30 AWG23
12
(6 pairs)
12/0.18
63.6 or
less
1.2 8.2 0.3
(Note 3)
20276 VSVPAWG#23×6P
KB-0492 (Bando Densen)
2 to 10
0.2 mm
2
12
(6 pairs)
40/0.08
105 or
less
0.88 7.2
(Note 3) A14B2339 6P
(Junkosha)
20 AWG24
12
(6 pairs)
40/0.08
105 or
less
0.88 7.2
(Note 3)
TPE SVP 40/0.08 (AWG#24 or
equivalent)-6P
KB-1928-2 (Bando Densen)
MR-EKCBL_M-H
30 to 50 AWG24
14
(7 pairs)
40/0.08
105 or
less
0.88 8.0
(Note 3)
TPE SVP 40/0.08 (AWG#24 or
equivalent)-7P
KB-1929-2 (Bando Densen)
MR-J3JSCBL03M-A1-L
MR-J3JSCBL03M-A2-L
0.3 AWG26
8
(4 pairs)
7/0.16
146 or
less
1.0 7.1 0.3
(Note 3)
VSVP 7/0.16 (AWG#26 or
equivalent)-4P
Ban-gi-shi-16822 (Bando Densen)
2 to 10
AWG22
6
(3 pairs)
7/0.26
53 or
less
1.18 7.1
(Note 3)
VSVP 7/0.26 (AWG#22 or
equivalent)-3P
KB-1655-2 (Bando Densen)
MR-J3ENSCBL_M-L
20/30 AWG23
12
(6 pairs)
12/0.18
63.3 or
less
1.2 8.2 0.3
(Note 3)
20276 VSVPAWG#23×6P
KB-0492 (Bando Densen)
2 to 10
AWG22
6
(3 pairs)
70/0.08
56 or
less
1.17 7.1
(Note 3)
TPE SVP 70/0.08 (AWG#22 or
equivalent)-3P
KB-2237-2 (Bando Densen)
Encoder
cable
MR-J3ENSCBL_M-H
20 to 50 AWG24
12
(6 pairs)
40/0.08
105 or
less
0.88 7.2
(Note 3)
TPE SVP 40/0.08 (AWG#24 or
equivalent)-6P
KB-1928-2 (Bando Densen)
Содержание MELSERVO-J3W Series
Страница 17: ...8 MEMO ...
Страница 27: ...1 FUNCTIONS AND CONFIGURATION 1 10 MEMO ...
Страница 87: ...4 STARTUP 4 14 MEMO ...
Страница 117: ...5 PARAMETERS 5 30 MEMO ...
Страница 129: ...6 GENERAL GAIN ADJUSTMENT 6 12 MEMO ...
Страница 185: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 241: ...11 OPTIONS AND AUXILIARY EQUIPMENT 11 56 MEMO ...
Страница 274: ...13 USING A LINEAR SERVO MOTOR 13 25 1 2 3 4 ...