14.6.3 Remedies for warnings
CAUTION
If Absolute position counter warning (E3. ) occurs, always make home position
setting again. Otherwise, it may cause an unexpected operation.
POINT
When any of the following alarms has occurred, do not cycle the power of the servo
amplifier repeatedly to restart. Doing so will cause a malfunction of the servo
amplifier and direct drive motor. If the power of the servo amplifier is switched
off/on during the alarms, allow more than 30 minutes for cooling before resuming
operation.
Excessive regeneration warning (E0. )
Main circuit device overheat warning (91. )
Overload warning (E1. )
Direct drive motor overheat warning (E2. )
When a warning whose stop system is "All axis" in the following table occurs, the servo amplifier will be the
servo-off status and the servo motor will stop at the warning occurrence. If any other warning occurs, operation
can be continued but an alarm may take place or proper operation may not be performed.
Eliminate the cause of the warning according to this section. Use MR Configurator to refer to the cause of
warning occurrence.
Warning No.: 91
Name: Main circuit device overheat warning
Stop method: No stop (common detection)
Warning description
The temperature inside of the servo amplifier reached a warning level.
Display
Detail name
Cause
Check method
Check result
Action
91.1 Main
circuit
device overheat
warning
91.2 Board
temperature
warning
Same as for the rotary servo motors.
Refer to section 8.4.
Alarm No.: 92
Name: Battery cable disconnection warning
Stop method: No stop (each-axis detection)
Warning description
Absolute position detection system battery voltage is low.
Display
Detail name
Cause
Check method
Check result
Action
It is not connected.
Connect the absolute
position storage unit.
1) The absolute position
storage unit has not
connected.
Check if the absolute
position storage unit is
connected.
It is connected.
Check 2).
Problem found.
Replace the battery.
Repair the cable.
2) Battery cable is
disconnected.
Check the battery cable.
No problem found.
Check 3).
It is below 3.0VDC.
Replace the battery.
3) Battery voltage dropped.
(detected by encoder)
Measure the battery
voltage.
It is 3.0VDC or more. Check 4).
92.1 Encoder
battery
disconnection
warning signal
detection
4) An encoder cable is
disconnected.
Check if the encoder
cable is disconnected.
It is disconnected.
Repair or replace the
encoder cable.
Содержание MELSERVO-J3W Series
Страница 17: ...8 MEMO ...
Страница 27: ...1 FUNCTIONS AND CONFIGURATION 1 10 MEMO ...
Страница 87: ...4 STARTUP 4 14 MEMO ...
Страница 117: ...5 PARAMETERS 5 30 MEMO ...
Страница 129: ...6 GENERAL GAIN ADJUSTMENT 6 12 MEMO ...
Страница 185: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 241: ...11 OPTIONS AND AUXILIARY EQUIPMENT 11 56 MEMO ...
Страница 274: ...13 USING A LINEAR SERVO MOTOR 13 25 1 2 3 4 ...