13. USING A LINEAR SERVO MOTOR
13 - 83
Alarm No.EB
Name: The other axis fault warning
Stop method: All axes stop (warning detected
at both axes)
Alarm description
In the other axis, alarm demanding all axes stop (11. , 15. , 17. , 24. and 32. ) is output.
Display Name
Cause
Checkpoint
Finding
Action
EB.1
The other axis
fault warning
Same as for the rotary servo motor.
Refer to section 8.4.
Alarm No.EC
Name: Overload warning 2
Stop method: Axes can operate (detected at
the corresponding axis)
Alarm description
The operation, in which current exceeding the rating flows intensively in any of U, V and W phases of the
servo motor, is repeated.
Display Name
Cause
Checkpoint
Finding
Action
EC.1 Overload
warning
2
Same as for the rotary servo motor.
Refer to section 8.4.
Alarm No.ED
Name: Output watt excess warning
Stop method: Axes can operate (detected at
the corresponding axis)
Alarm description
The status, in which the output wattage (speed x torque) of the servo motor exceed the rated output,
continues steadily.
Display Name
Cause
Checkpoint
Finding
Action
ED.1 Output
watt
excess
Same as for the rotary servo motor.
Refer to section 8.4.
Содержание MELSERVO-J3W Series
Страница 17: ...8 MEMO ...
Страница 27: ...1 FUNCTIONS AND CONFIGURATION 1 10 MEMO ...
Страница 87: ...4 STARTUP 4 14 MEMO ...
Страница 117: ...5 PARAMETERS 5 30 MEMO ...
Страница 129: ...6 GENERAL GAIN ADJUSTMENT 6 12 MEMO ...
Страница 185: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 241: ...11 OPTIONS AND AUXILIARY EQUIPMENT 11 56 MEMO ...
Страница 274: ...13 USING A LINEAR SERVO MOTOR 13 25 1 2 3 4 ...