APPENDIX
App. - 12
(8) About wiring protection
For installation in United States, branch circuit protection must be provided, in accordance with the National
Electrical Code and any applicable local codes and per the table below.
For installation in Canada, branch circuit protection must be provided, in accordance with the Canada
Electrical Code and any applicable provincial codes and per the table below.
Use the molded-case circuit breaker or a Class T fuse indicated in the table below.
(a) MR-J3W-0303BN6
Power supply specification
Circuit protector (Note)
Control circuit power supply (24VDC)
CP30-BA 1P 1-M 1A
Main circuit power supply (48VDC)
CP30-BA 1P 1-M 5A
Control circuit power supply/Main
circuit power supply (24VDC)
CP30-BA 1P 1-M 10A
Note. For operation characteristics, use an intermediate speed type.
(b) MR-J3W-22B to MR-J3W-1010B
Molded-case circuit breaker (Note)
Fuse
Servo motor total output
Current
Voltage AC [V]
Current [A]
Voltage AC [V]
300W or less
30A frame 5A
15
From over 300W to 600W
30A frame 10A
20
From over 600W to 1kW
30A frame 15A
240
20
300
From over 1kW to 2.0kW
30A frame 20A
30
Note. Listed no-fuse breakers are for when the power factor improving reactor is not used.
(9) Options, peripheral devices
Use the UL/CSA Standard-compliant products.
(10) Connection example
(a) MR-J3W-0303BN6
Servo amplifier
CNP1
U
V
W
U
V
W
A-axis servo motor
CNP2A
U
V
W
U
V
W
B-axis servo motor
CNP2B
24
0
PM
Circuit
protector
Relay
24VDC
48VDC
Circuit
protector
24VDC
Main circuit
power supply: 24VDC
Main circuit
power supply: 48VDC
Содержание MELSERVO-J3W Series
Страница 17: ...8 MEMO ...
Страница 27: ...1 FUNCTIONS AND CONFIGURATION 1 10 MEMO ...
Страница 87: ...4 STARTUP 4 14 MEMO ...
Страница 117: ...5 PARAMETERS 5 30 MEMO ...
Страница 129: ...6 GENERAL GAIN ADJUSTMENT 6 12 MEMO ...
Страница 185: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 241: ...11 OPTIONS AND AUXILIARY EQUIPMENT 11 56 MEMO ...
Страница 274: ...13 USING A LINEAR SERVO MOTOR 13 25 1 2 3 4 ...