5. PARAMETERS
5 - 2
5.1.1 Parameter list
No. Symbol
Name
Setting
(Note 1)
Factory
setting
(Note 2)
Unit
PA01 **STY Control mode
Each axis
0000h
PA02 **REG Regenerative
option
Common 0000h
PA03 *ABS Absolute
position detection system
Each axis
0000h
PA04 *AOP1 Function selection A-1
Common
0000h
PA05
This parameter is not used. Do not change the value.
0
PA06
1
PA07
1
PA08
ATU
Auto tuning mode
Each axis
0001h
PA09
RSP
Auto tuning response
Each axis
12
PA10
INP
In-position range
Each axis
100
pulse
PA11
This parameter is not used. Do not change the value.
1000.0
PA12
1000.0
PA13
0000h
PA14
*POL Rotation direction selection
Each axis
0
PA15
*ENR Encoder output pulses
Each axis
4000
pulse/rev
PA16 *ENR2 Encoder output pulses 2
Each axis
0
PA17
This parameter is not used. Do not change the value.
0000h
PA18
0000h
PA19
*BLK Parameter write inhibit
Each axis
000Bh
Note 1. Each axis: Set a value for each of the A-axis and the B-axis.
Common: Common parameters for the A-axis and the B-axis. Set same values for the A-axis and the B-axis. If different values are
set, the last set value becomes valid.
2. Valid for the A-axis and the B-axis.
Содержание MELSERVO-J3W Series
Страница 17: ...8 MEMO ...
Страница 27: ...1 FUNCTIONS AND CONFIGURATION 1 10 MEMO ...
Страница 87: ...4 STARTUP 4 14 MEMO ...
Страница 117: ...5 PARAMETERS 5 30 MEMO ...
Страница 129: ...6 GENERAL GAIN ADJUSTMENT 6 12 MEMO ...
Страница 185: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 241: ...11 OPTIONS AND AUXILIARY EQUIPMENT 11 56 MEMO ...
Страница 274: ...13 USING A LINEAR SERVO MOTOR 13 25 1 2 3 4 ...