5. PARAMETERS
5 - 21
5.3.3 Analog monitor
The servo status can be output to two channels in terms of voltage.
(1) Setting
Change the following digits of parameter No.PC09, PC10.
0 0
Parameter No.PC09
Analog monitor (MO1) output selection
(Signal output to across MO1-LG)
Analog monitor (MO1) output axis selection
0: A-axis
1: B-axis
0 0
Parameter No.PC10
Analog monitor (MO2) output selection
(Signal output to across MO2-LG)
Analog monitor (MO2) output axis selection
0: A-axis
1: B-axis
Parameters No.PC11 and PC12 can be used to set the offset voltages to the analog output voltages. The
setting range is between 999 and 999mV.
Parameter No.
Description
Setting range [mV]
PC11
Used to set the offset voltage for the analog monitor 1 (MO1).
PC12
Used to set the offset voltage for the analog monitor 2 (MO2).
999 to 999
(2) Set content
The servo amplifier is factory-set to output the servo motor speed to analog monitor 1 (MO1) and the torque
to analog monitor (MO2). The setting can be changed as listed below by changing the parameter No.PC09
and PC10 value.
Refer to (3) for the measurement point.
Setting
Output item
Description
Setting
Output item
Description
0
Servo motor speed
Max. speed
CW direction
CCW direction
Max. speed
0
8[V]
-8[V]
1 Torque
Max. torque
Driving in CW
direction
Driving in CCW
direction
Max. torque
0
8[V]
-8[V]
2
Servo motor speed
CCW direction
Max. speed
Max. speed
0
8[V]
CW direction
3 Torque
Driving in CCW
direction
Max. torque
Max. torque
0
8[V]
Driving in CW
direction
Содержание MELSERVO-J3W Series
Страница 17: ...8 MEMO ...
Страница 27: ...1 FUNCTIONS AND CONFIGURATION 1 10 MEMO ...
Страница 87: ...4 STARTUP 4 14 MEMO ...
Страница 117: ...5 PARAMETERS 5 30 MEMO ...
Страница 129: ...6 GENERAL GAIN ADJUSTMENT 6 12 MEMO ...
Страница 185: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 241: ...11 OPTIONS AND AUXILIARY EQUIPMENT 11 56 MEMO ...
Страница 274: ...13 USING A LINEAR SERVO MOTOR 13 25 1 2 3 4 ...