14. USING A DIRECT DRIVE MOTOR
14 - 20
(c) State transition of the servo amplifier display (3-digit, 7-segment LED) at the magnetic pole detection
When the magnetic pole detection with MR Configurator is normally executed, the servo amplifier
display (3-digit, 7-segment LED) shows the state as below.
Servo-off status
Detecting
magnetic poles
Magnetic pole
detection
completed
(servo-on status)
Decimal point flickers.
14.4.3 Operation from controller
To configure the absolute position detection system by using the direct drive motor, the battery unit (MR-
BTCASE MR-BAT 8) and the absolute position storage unit MR-BTAS01 are required.
The direct drive servo can be used with any of the following controllers.
Servo system controller
Model
Software version (Note)
SV13/SV22
00H or above
Q17 DCPU
SV43
00B or above
Motion controller
SV13/SV22
00G or above
Q170MCPU
SV43
QD75MH
101120000000000-B or above
Positioning module
LD77MH
All software versions
Note. For software versions and other details, refer to each servo system controller manual.
(1) Operation method
Positioning operation from the controller is basically performed like the MR-J3W- B servo amplifier.
For the incremental system, the magnetic pole detection is automatically performed at the first servo-on
after the power-on. For this reason, when performing the positioning operation, create the sequence which
surely confirms the servo-on status as the inter lock condition of the positioning command.
Also, some parameter settings and the home position return differ according to the controller type.
Содержание MELSERVO-J3W Series
Страница 17: ...8 MEMO ...
Страница 27: ...1 FUNCTIONS AND CONFIGURATION 1 10 MEMO ...
Страница 87: ...4 STARTUP 4 14 MEMO ...
Страница 117: ...5 PARAMETERS 5 30 MEMO ...
Страница 129: ...6 GENERAL GAIN ADJUSTMENT 6 12 MEMO ...
Страница 185: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 241: ...11 OPTIONS AND AUXILIARY EQUIPMENT 11 56 MEMO ...
Страница 274: ...13 USING A LINEAR SERVO MOTOR 13 25 1 2 3 4 ...