A - 4
CAUTION
When you keep or use it, please fulfill the following environmental conditions.
Environment
Item
Servo amplifier
Servo motor
[ ] 0 to 55 (non-freezing)
0 to 40 (non-freezing)
Operation
[ ] 32 to 131 (non-freezing)
32 to 104 (non-freezing)
[ ]
20 to 65 (non-freezing)
15 to 70 (non-freezing)
Ambient
temperature
Storage
[ ]
4 to 149 (non-freezing)
5 to 158 (non-freezing)
Operation 90 RH or less (non-condensing)
80 RH or less (non-condensing)
Ambient
humidity
Storage 90 RH or less (non-condensing)
Ambience
Indoors (no direct sunlight) Free from corrosive gas, flammable gas, oil mist, dust and dirt
Altitude
Max. 1000m above sea level
HF-MP series
HF-KP series
X, Y: 49 m/s
2
HF-SP51 52
HC-UP72
HF-JP53 73 103
X, Y: 24.5 m/s
2
(Note)
Vibration resistance
HC-LP52
X: 9.8 m/s
2
Y: 24.5 m/s
2
5.9 m/s
2
at 10 to 55Hz
(directions of X, Y and Z axes)
HG-AK series
X, Y: 49 m/s
2
Note. Except the servo motor with a reduction gear.
Wire the equipment correctly and securely. Otherwise, the servo motor may operate unexpectedly.
Do not install a power capacitor, surge killer or radio noise filter (FR-BIF option) between the servo motor
and servo amplifier.
Connect the wires to the correct phase terminals (U, V, W) of the servo amplifier and servo motor.
Not doing so may cause unexpected operation.
Connect the servo amplifier power output (U, V, and W) to the servo motor power input (U, V, and W)
directly. Do not let a magnetic contactor, etc. intervene. Otherwise, it may cause a malfunction.
U
Servo motor
M
V
W
U
V
W
Servo amplifier
U
M
V
W
U
V
W
Servo motor
Servo amplifier
Содержание MELSERVO-J3W Series
Страница 17: ...8 MEMO ...
Страница 27: ...1 FUNCTIONS AND CONFIGURATION 1 10 MEMO ...
Страница 87: ...4 STARTUP 4 14 MEMO ...
Страница 117: ...5 PARAMETERS 5 30 MEMO ...
Страница 129: ...6 GENERAL GAIN ADJUSTMENT 6 12 MEMO ...
Страница 185: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 241: ...11 OPTIONS AND AUXILIARY EQUIPMENT 11 56 MEMO ...
Страница 274: ...13 USING A LINEAR SERVO MOTOR 13 25 1 2 3 4 ...