13. USING A LINEAR SERVO MOTOR
13 - 81
Alarm No.96
Name: Home position setting warning
Stop method: Axes can operate (detected by
the corresponding axis).
Alarm description
Home positioning cannot be made.
Display Name
Cause
Checkpoint
Finding
Action
96.1
INP error at
home positioning
Same as for the rotary servo motor.
Refer to section 8.4.
96.2 Command
input
error at home
positioning
Alarm No.E0
Name: Excessive regeneration warning
Stop method: Axes can operate (warning
detected at both axes)
Warning description
There is a possibility that regenerative power may exceed permissible regenerative power of built-in
regenerative resistor or regenerative option.
Display Name
Cause
Checkpoint
Finding
Action
E0.1 Excessive
regeneration
warning
Same as for the rotary servo motor.
Refer to section 8.4.
Alarm No.E1
Name: Overload warning 1
Stop method: Axes can operate (detected at
the corresponding axis)
Alarm description
There is a possibility that overload alarm (50. , 51. ) may occur.
Display Name
Cause
Checkpoint
Finding
Action
E1.1 Thermal
overload
warning 1 during
operation
Same as for the rotary servo motor.
Refer to section 8.4.
E1.2 Thermal
overload
warning 2 during
operation
E1.3 Thermal
overload
warning 3 during
operation
E1.4 Thermal
overload
warning 4 during
operation
E1.5 Thermal
overload
warning 1 during
a stop
E1.6 Thermal
overload
warning 2 during
a stop
E1.7 Thermal
overload
warning 3 during
a stop
E1.8 Thermal
overload
warning 4 during
a stop
Содержание MELSERVO-J3W Series
Страница 17: ...8 MEMO ...
Страница 27: ...1 FUNCTIONS AND CONFIGURATION 1 10 MEMO ...
Страница 87: ...4 STARTUP 4 14 MEMO ...
Страница 117: ...5 PARAMETERS 5 30 MEMO ...
Страница 129: ...6 GENERAL GAIN ADJUSTMENT 6 12 MEMO ...
Страница 185: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 241: ...11 OPTIONS AND AUXILIARY EQUIPMENT 11 56 MEMO ...
Страница 274: ...13 USING A LINEAR SERVO MOTOR 13 25 1 2 3 4 ...