5. PARAMETERS
5 - 28
5.5.2 List of details
No.
Symbol
Name and function
Setting
Factory
setting
Unit
Setting
range
Po01 *OOP1 Function selection O-1
Used to set alarms that activate the other axis fault warning (EB).
The other axis fault warning (EB) activating alarm
selection
0: 11, 15, 17, 24 and 32 only
1: All alarms
The other axis fault warning (EB) is not activated by the
alarms, which occur in the A-axis and the B-axis
simultaneously, regardless of their alarm numbers.
0
0
0
Common 0000h
Refer
to
Name
and
function
column.
Po02 SGRA Axis selection for graphing analog data (MR Configurator)
Used to select axes that obtain analog data and triggered data in the MR
Configurator's graph function.
Axis selection for analog data ch1
0: Axis that communicates with MR Configurator
1: Axis that does not communicate with MR Configurator
Axis selection for analog data ch2
The setting is same as the ch1.
Axis selection for analog data ch3
The setting is same as the ch1.
Axis selection for triggered data
The setting is same as the ch1.
Select the axis that obtains triggered data. This setting
is valid for analog and digital trigger sources.
Common 0000h
Refer
to
Name
and
function
column.
Po03 SGRD Axis selection for graphing digital data (MR Configurator)
Used to select the axes that obtain digital data in the MR Configurator's graph
function.
Axis selection for digital data ch1
0: Axis that communicates with MR Configurator
1: Axis that does not communicate with MR Configurator
Axis selection for digital data ch2
The setting is same as the ch1.
Axis selection for digital data ch3
The setting is same as the ch1.
Axis selection for digital data ch4
The setting is same as the ch1.
Common 0000h
Refer
to
Name
and
function
column.
Содержание MELSERVO-J3W Series
Страница 17: ...8 MEMO ...
Страница 27: ...1 FUNCTIONS AND CONFIGURATION 1 10 MEMO ...
Страница 87: ...4 STARTUP 4 14 MEMO ...
Страница 117: ...5 PARAMETERS 5 30 MEMO ...
Страница 129: ...6 GENERAL GAIN ADJUSTMENT 6 12 MEMO ...
Страница 185: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 241: ...11 OPTIONS AND AUXILIARY EQUIPMENT 11 56 MEMO ...
Страница 274: ...13 USING A LINEAR SERVO MOTOR 13 25 1 2 3 4 ...