8. TROUBLESHOOTING
8 - 20
Alarm No.36
Name: SSCNET receive error 2
Stop method: Corresponding axis stops
Alarm description
SSCNET communication error (Continuous communication error for about 70ms.)
Display Name
Cause
Checkpoint
Finding
Action
36.1 Continuous
communication
data error
(1) SSCNET cable is
disconnected.
Check the cable
connection.
Disconnected.
Turn off the power of
servo amplifier, and
connect the cable.
Connected properly.
Check (2).
(2) Tip of SSCNET cable
has dirt.
Not reproduced.
Take measure to keep
cable tip clean.
Wipe off the dirt from the
cable tip, and check
reproducibility.
Reproduced. Check
(3).
(3)
Check the cable.
Problem found.
Replace the cable.
SSCNET cable is
broken or cut off.
No problem found.
Check (4).
(4)
Check if the condition
stated in the left meets.
Meets. Take
countermeasure.
Vinyl tape is stacked to
SSCNET cable, or
cable containing
migrating plasticizer is
adhered to the cable.
Does not meet.
Check (5).
(5) Servo amplifier is faulty.
Not reproduced.
Replace the servo
amplifier.
Replace the servo
amplifier and check the
reproducibility of the error. Reproduced. Check
(6).
(6) Servo amplifier in front or
rear axis of alarm
occurring axis is faulty.
Reproduced in the
rear axis of the
corresponding axis.
Replace the servo
amplifier.
Replace front and rear
axes of alarm occurring
axis, and check the
reproducibility of the error. Not reproduced.
Check (7).
(7) Fault is generated from
the surrounding
environment.
Check for noise, etc.
Problem found.
Take countermeasure
according to the
cause.
Alarm No.37
Name: Parameter error
Stop method: Corresponding axis stops
Alarm description
Settings in the servo amplifier are incorrect.
Display Name
Cause
Checkpoint
Finding
Action
37.1 Parameter
setting
range error
(1)
Check the parameter
number, and check the
setting of the controller.
Outside of the range.
Change parameter
value to within the
setting range.
There is a parameter of
which value is set outside
of the setting range.
Within the range.
Check (2).
(2)
Abnormal values are
written.
Replace the servo
amplifier.
EEP-ROM fault caused
by parameter write times
over.
Write parameter values
within the setting range,
and check that values are
written correctly.
Values are written
correctly.
Check (3).
(3) Servo amplifier fault
caused the parameter
setting to be rewritten.
Replace the servo
amplifier and check the
reproducibility of the error.
Not reproduced.
Use the newly
replaced servo
amplifier.
37.2 Parameter
combination error
(1) One parameter setting
contradicts another.
Check parameter
numbers, and check the
setting values.
Problem found in the
setting values.
Correct the setting
value.
Содержание MELSERVO-J3W Series
Страница 17: ...8 MEMO ...
Страница 27: ...1 FUNCTIONS AND CONFIGURATION 1 10 MEMO ...
Страница 87: ...4 STARTUP 4 14 MEMO ...
Страница 117: ...5 PARAMETERS 5 30 MEMO ...
Страница 129: ...6 GENERAL GAIN ADJUSTMENT 6 12 MEMO ...
Страница 185: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 241: ...11 OPTIONS AND AUXILIARY EQUIPMENT 11 56 MEMO ...
Страница 274: ...13 USING A LINEAR SERVO MOTOR 13 25 1 2 3 4 ...