background image

®

MADE

USA

IN THE

PROFESSIONAL POWER AMPLIFIER

9 5 0 5

Installation & Operation

PROFESSIONAL POWER AMPL

nova

trans

®

Содержание trans-nova 9505

Страница 1: ...MADE USA IN THE PROFESSIONAL POWER AMPLIFIER 9505 Installation Operation PROFESSIONAL POWER AMPL nova trans...

Страница 2: ...of the equipment s plug be able to fully insert into the mating receptacle Never remove the round grounding pin on the plug in an attempt to mate to a two wire ungrounded receptacle use a grounding ad...

Страница 3: ...Range 800mV 8 per phase balanced 690mV 4 per phase balanced In Out Gain 29dB maximum Damping Factor 1000 to 1kHz 100 to 10kHz 20 to 100kHz Power Consumption 160W 2A 120VAC Idle Power Both Channels Dr...

Страница 4: ...Unbalanced Source with Balanced Input 4 Output Connections 4 Monophonic Use 4 OPERATION Power Switch 5 Input Switch 6 Ground Switch 6 Mono Switch 6 Load Fault Protection 6 Warm Up 6 Cleaning and Maint...

Страница 5: ...nstallationandOperationportionsofthismanualbeforeputting theamplifierintoservice The circuitry used in the 9505 is the latest refinement of our trans nova TRANSconductance NOdal Voltage Amplifier USPa...

Страница 6: ...Use CH 1 Input Only CHANNEL 1 CH 2 120 VAC 60Hz 1800W MAX Audio GND Chass Float Phone Connections CHANNEL 1 Mono 2 Ch Unbal Bal A Division of Rockford Corp Tempe AZ 85281 U S A Made in the U S A CH 1...

Страница 7: ...20cm hinter der Front des Verst rkers angebracht werden Per i sistemi ad armadio sono necessari due ventilatori direzionati in su collocati dai 10 ai 13 centimetri davanti all amplificatore Inadequat...

Страница 8: ...inputs use conventional RCA phone jacks Set the BALANCED UNBALANCED switch to the UNBALANCED position to use these jacks BALANCED INPUT The input jacks located on the back of the amplifier are dual fu...

Страница 9: ...quoi pour les op rations conduites en mono nous recommandons l utilisation d une charge de huit ohm comme imp dance minimale Wird der Verst rker gebr ckt sieht dieser nur die halbe angelegte Last Aus...

Страница 10: ...FLOAT switch allows you to select the amplifier grounding scheme for best system compatibility With the switch in the CHASSIS position all signal grounds are referred to the chassis and power line gro...

Страница 11: ...7 PC BO A R D LA Y O U T...

Страница 12: ...Designators 1 99 Left Channel 101 199 Right Channel 201 299 Common Parts 301 399 Chassis Power Supply 4 Left Channel Only Shown 5 Stereo Mono Switch Shown in Stereo 6 Balanced Unbalanced Switch Shown...

Страница 13: ...9...

Страница 14: ...MS R1 R101 47 5k 1 4W 1 RM 4 4752C R2 R102 47 5k 1 4W 1 RM 4 4752C R3 R103 1k 1 4W 5 RM 4 102C R4 R104 1k 1 4W 5 RM 4 102C R5 R105 2 2M 1 4W 5 RM 4 225C R6 R106 100 1 4W 5 RM 4 101C R7 R107 22k 1 4W 5...

Страница 15: ...SSH 609 IEC Connector CC 0918 IEC Line Cord FA 0209 Dual Binding Post CC 0867 MOSFET Insulator HWH 442 J2 J102 XLR 1 4 Connector CC 0588 J20 RCA Connector CCH 228 Components marked with this symbol ar...

Страница 16: ...FIER SERVO INTEGRATOR SOFT TURN ON OFF SYSTEM RIGHT CH AMPLIFIER RIGHT CH HIGH VOLTAGE POWER SUPPLY LEFT CH HIGH VOLTAGE POWER SUPPLY LOW VOLTAGE POWER SUPPLY BUFFER BUFFER STEREO MONO SWITCH BUFFER B...

Страница 17: ...cations are very good the numbers do not describe the realistic sound of the amplifiers CIRCUIT IMPLEMENTATION Earlier models of amplifiers we have offered using the trans nova topology have earned th...

Страница 18: ...y each feeding a conventional split full wave bridge rectifier High voltage power supply capacitance is 20 000 F per rail for each channel of the 9505 The third transformer secondary feeds a regulated...

Страница 19: ...rvice performed by anyone other than Hafler or an Authorized Hafler service center 3 Any product purchased outside the United States please contact your local dealer 4 Shipping charges to get the unit...

Страница 20: ...tensiones deben proveer de la misma conecci n aterrada de tres hiles Es importante que el enchufe se pueda introducir comjpletamente en el recept culo Nunca remeva el pin de aterramiento en un intento...

Страница 21: ...consell e moins d tre en mesure de fournir la charge lectrique requise un fonctionement sans risque de tout mat riel reli 11 P RIODES DE NON UTILISATON Durant les p riodes de non utilisation la prise...

Страница 22: ...dies die erforderlichen Str me bertragen k nnen Benutzen Sie immer dreiadrige Verl ngerungskable 11 ZEITR UME IN DENE DAS GER AT NICHT GENUTZT WIRD Wird das Ger t ber einen l ngeren Zeitraum nicht ge...

Страница 23: ...uesti non garantiscono la potenza sufficiente per i corretto fuinzionamento degli apparati connessi E alters importante che vengano sempre impiegate prolunghe con la configurazaione a tre fili con ter...

Страница 24: ...MAN 0587 E 8 97 HAFLER PROFESSIONAL A DIVISION OF ROCKFORD CORPROATION 546 SOUTH ROCKFORD DRIVE TEMPE ARIZONA 85281 U S A IN U S A 602 967 3565 IN EUROPE FAX 49 8503 934014 IN JAPAN FAX 81 559 79 1265...

Отзывы: