14. USING A DIRECT DRIVE MOTOR
14 - 39
No. Symbol
Name and function
Each/
common
Default
value
Unit
Setting
range
PS17 LTSTS Minute position detection method function selection
Set the response and the load to motor inertia moment ratio of the minute position
detection method.
To make the parameter valid, set parameter No.PS08 (Special function selection 3)
to "
4" (minute position detection method). (Refer to section 14.4.2 (5).)
Low response
High response
Response of the minute position detection
method
0 0
Setting
Response
Setting
Response
0
8
1
9
2
A
3
B
4
C
5
D
6
E
7
F
Middle response
Middle response
Setting
Load inertia
moment ratio
Setting
7
F
150 times or more
70 times
0
8
1
9
2
A
3
B
4
C
5
D
6
E
Less than 10 times
80 times
90 times
10 times
100 times
20 times
110 times
30 times
120 times
40 times
130 times
50 times
140 times
60 times
Load inertia
moment ratio
Selecting the load inertia moment ratio at the
direct drive motor, which decides the response of
the minute position detection method
Each 0000h Refer
to
Name
and
function
column.
PS18 IDLV Minute position detection method identification signal amplitude
Used to set the identification signal amplitude for the minute position detection
method. To make the parameter valid, set parameter No.PS08 (Special function
selection 3) to "
4". Identification signal is "100 " when "0000h" is set. (Refer
to section 14.4.2 (5).)
Each 0000h
0000h
to
006Fh
PS19
This parameter is not used. Do not change this value by any means.
0000h
PS20
0000h
PS21
0000h
PS22
0000h
PS23
0000h
PS24
0000h
PS25
0000h
PS26
0000h
PS27
0000h
PS28
0000h
PS29
0000h
PS30
0000h
PS31
0000h
PS32
0000h
Содержание MELSERVO-J3W Series
Страница 17: ...8 MEMO ...
Страница 27: ...1 FUNCTIONS AND CONFIGURATION 1 10 MEMO ...
Страница 87: ...4 STARTUP 4 14 MEMO ...
Страница 117: ...5 PARAMETERS 5 30 MEMO ...
Страница 129: ...6 GENERAL GAIN ADJUSTMENT 6 12 MEMO ...
Страница 185: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 241: ...11 OPTIONS AND AUXILIARY EQUIPMENT 11 56 MEMO ...
Страница 274: ...13 USING A LINEAR SERVO MOTOR 13 25 1 2 3 4 ...