14. USING A DIRECT DRIVE MOTOR
14 - 51
Alarm No.: 34
Name: SSCNET receive error 1
Stop system: Each axis
Alarm content
SSCNET communication is malfunctioning. (continuous communication error with 3.5ms interval)
Display
Detail name
Cause
Check method
Check result
Action
34.1 SSCNET
receive data
error
34.2 SSCNET
communication
connector
connection
error
34.3 SSCNET
communication
data error
34.4 Hardware
error
signal detection
Same as for the rotary servo motors.
Refer to section 8.3.
Alarm No.: 35
Name: Command frequency error
Stop system: Each axis
Alarm content
Input pulse frequency of command pulse is too high.
Display
Detail name
Cause
Check method
Check result
Action
35.1 Command
frequency error
Same as for the rotary servo motors.
Refer to section 8.3.
Alarm No.: 36
Name: SSCNET receive error 2
Stop system: Each axis
Alarm content
SSCNET communication is malfunctioning. (intermittent communication error with about 70ms interval)
Display
Detail name
Cause
Check method
Check result
Action
36.1 Continuous
communication
data error
Same as for the rotary servo motors.
Refer to section 8.3.
Alarm No.: 37
Name: Parameter error
Stop system: Each axis
Alarm content
Parameter setting is incorrect.
Display
Detail name
Cause
Check method
Check result
Action
37.1 Parameter
setting range
error
37.2 Parameter
combination
error
Same as for the rotary servo motors.
Refer to section 8.3.
Содержание MELSERVO-J3W Series
Страница 17: ...8 MEMO ...
Страница 27: ...1 FUNCTIONS AND CONFIGURATION 1 10 MEMO ...
Страница 87: ...4 STARTUP 4 14 MEMO ...
Страница 117: ...5 PARAMETERS 5 30 MEMO ...
Страница 129: ...6 GENERAL GAIN ADJUSTMENT 6 12 MEMO ...
Страница 185: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 241: ...11 OPTIONS AND AUXILIARY EQUIPMENT 11 56 MEMO ...
Страница 274: ...13 USING A LINEAR SERVO MOTOR 13 25 1 2 3 4 ...