15. MR-J3W-0303BN6 SERVO AMPLIFIER
15 - 38
15.5.2 Extension setting parameters (No.PC
)
(1) Detail list
No.
Symbol
Name and function
Each/
common
Default
value
Unit
Setting
range
PC09 MOD1 Analog monitor 1 output
Select a signal to output to Analog monitor 1 (MO1). (Refer to (2) of this section.)
5
6
7
8
9
D
0
1
2
3
4
Analog monitor 1 (MO1) output selection
Setting
Servo motor speed (10 4V/max. speed)
Torque (10 4V/max. torque)
Servo motor speed (10 4V/max. speed)
Torque (10 4V/max. torque)
Current command (10 4V/max. current command)
Speed command (10 4V/max. speed)
Droop pulses (10 5V/100 pulses)
Droop pulses (10 5V/1000 pulses)
Droop pulses (10 5V/10000 pulses)
Droop pulses (10 5V/100000 pulses)
Bus voltage (10 5V/400V)
Item
0 0
Analog monitor 1 (MO1) output axis selection
0: A-axis
1: B-axis
E
Speed command 2 (10 4V/max. speed)
Common 0000h
Refer to
Name
and
function
column.
PC10 MOD2 Analog monitor 2 output
Select a signal to output to Analog monitor 2 (MO2). (Refer to (2) of this section.)
Analog monitor 2 (MO2) output selection
The settings are the same as those of parameter
No.PC09.
0 0
Analog monitor 2 (MO2) output axis selection
The settings are the same as those of parameter
No.PC09.
Common 0001h
Refer to
Name
and
function
column.
Содержание MELSERVO-J3W Series
Страница 17: ...8 MEMO ...
Страница 27: ...1 FUNCTIONS AND CONFIGURATION 1 10 MEMO ...
Страница 87: ...4 STARTUP 4 14 MEMO ...
Страница 117: ...5 PARAMETERS 5 30 MEMO ...
Страница 129: ...6 GENERAL GAIN ADJUSTMENT 6 12 MEMO ...
Страница 185: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 241: ...11 OPTIONS AND AUXILIARY EQUIPMENT 11 56 MEMO ...
Страница 274: ...13 USING A LINEAR SERVO MOTOR 13 25 1 2 3 4 ...