14. USING A DIRECT DRIVE MOTOR
14 - 60
Warning No.: EB
Name: The other axis error warning
Stop system: All axes (each-axis detection)
Warning description
In the other axis, an alarm demanding all axes stop (11. , 15. , 17. , 24. , and 32. ) occurred.
Display
Detail name
Cause
Check method
Check result
Action
EB.1 The other axis
error warning
Same as for the rotary servo motors.
Refer to section 8.4.
Warning No.: EC
Name: Overload warning 2
Stop method: No stop (each-axis detection)
Warning description
Operation, in which a current exceeding the rating flew intensively in any of the U, V, and W phases of the
servo motor, was repeated.
Display
Detail name
Cause
Check method
Check result
Action
EC.1 Overload
warning 2
Same as for the rotary servo motors.
Refer to section 8.4.
Warning No.: ED
Name: Output watt excess warning
Stop method: No stop (each-axis detection)
Warning description
The status, in which the output wattage (speed torque) of the direct drive motor exceeded the rated output,
continued steadily.
Display
Detail name
Cause
Check method
Check result
Action
ED.1 Output
watt
excess
Same as for the rotary servo motors.
Refer to section 8.4.
Содержание MELSERVO-J3W Series
Страница 17: ...8 MEMO ...
Страница 27: ...1 FUNCTIONS AND CONFIGURATION 1 10 MEMO ...
Страница 87: ...4 STARTUP 4 14 MEMO ...
Страница 117: ...5 PARAMETERS 5 30 MEMO ...
Страница 129: ...6 GENERAL GAIN ADJUSTMENT 6 12 MEMO ...
Страница 185: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 241: ...11 OPTIONS AND AUXILIARY EQUIPMENT 11 56 MEMO ...
Страница 274: ...13 USING A LINEAR SERVO MOTOR 13 25 1 2 3 4 ...