13. USING A LINEAR SERVO MOTOR
13 - 59
Alarm deactivation
Display Name
Power
OFF ON
Error reset
CPU reset
Detection
method
(Note 3)
Stop
method
(Note 4)
91
Main circuit device overheat warning
Common
96
Home position setting warning
Each axis
E0
Excessive regeneration warning
Common
E1
Overload warning 1
Each axis
E2
Linear servo motor overheat warning
Each axis
E4 Parameter
warning
Each axis
E6
Servo forced stop warning
Common
All axis
E7
Controller forced stop warning
Common
All axis
E8
Cooling fan speed reduction warning
Common
E9
Main circuit off warning
Common All
axis
EB
The other axis fault warning
Each axis
All axis
EC
Overload warning 2
Each axis
Wam
ings
ED
Output watt excess warning
Each axis
Note 1. Deactivate the alarm about 30 minutes of cooling time after removing the cause of occurrence.
2. In some controller communication status, the alarm factor may not be removed.
3. Alarms and warnings are detected in the following axes.
Each axis: Alarms and warnings are detected in the A-axis and the B-axis separately.
Common: Alarms and warnings are detected in the A-axis and the B-axis together.
4. When an alarm or a warning occurs, the axes stop as below.
Each axis: Only the axis that detected the alarm or warning stops.
All axis: All axes stop.
5. The alarm can be deactivated by setting parameter No.PS04 to "1
."
Содержание MELSERVO-J3W Series
Страница 17: ...8 MEMO ...
Страница 27: ...1 FUNCTIONS AND CONFIGURATION 1 10 MEMO ...
Страница 87: ...4 STARTUP 4 14 MEMO ...
Страница 117: ...5 PARAMETERS 5 30 MEMO ...
Страница 129: ...6 GENERAL GAIN ADJUSTMENT 6 12 MEMO ...
Страница 185: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 241: ...11 OPTIONS AND AUXILIARY EQUIPMENT 11 56 MEMO ...
Страница 274: ...13 USING A LINEAR SERVO MOTOR 13 25 1 2 3 4 ...