13. USING A LINEAR SERVO MOTOR
13 - 17
13.5.2 Magnetic pole detection
Make sure to perform the magnetic pole detection before starting the positioning operation in order to match the
positional relationship between the linear servo motor and the linear encoder.
(1) Preparation for the magnetic pole detection
POINT
When the test operation mode is selected by using the test operation select switch
(SW2-1), the SSCNET communication for the servo amplifier in the test
operation mode and the following servo amplifiers is blocked.
For the magnetic pole detection, the test operation mode (positioning operation) of MR Configurator is used.
Turn the power of servo amplifier off and set the test operation select switch (SW2-1) as shown below. By
turning the power on, it switches to the test operation mode.
C
B
7
9
6
8
5
4
3
2
1
0
F
E
D
A
1
2
ON 4E
SW1
SW2
TEST
SW2
DOWN
UP
1
2
Set SW2-1 to "UP"
(2) Magnetic pole detection
WARNING
Note that the magnetic pole detection is automatically started simultaneously with
turning ON the servo-on command.
CAUTION
If the magnetic pole detection is not executed properly, the linear servo motor may
run unexpectedly.
Содержание MELSERVO-J3W Series
Страница 17: ...8 MEMO ...
Страница 27: ...1 FUNCTIONS AND CONFIGURATION 1 10 MEMO ...
Страница 87: ...4 STARTUP 4 14 MEMO ...
Страница 117: ...5 PARAMETERS 5 30 MEMO ...
Страница 129: ...6 GENERAL GAIN ADJUSTMENT 6 12 MEMO ...
Страница 185: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 241: ...11 OPTIONS AND AUXILIARY EQUIPMENT 11 56 MEMO ...
Страница 274: ...13 USING A LINEAR SERVO MOTOR 13 25 1 2 3 4 ...