13. USING A LINEAR SERVO MOTOR
13 - 31
(2) Servo system controller setting
(a) Setting instructions
The following servo parameters will be valid by turning the power of servo amplifier off once and then
turning it on again after writing to the servo amplifier from the controller.
Setting description
Setting item
Motion controller
Q17 DCPU/
Q17 HCPU/Q170MCPU
(Note 3) Positioning
QD74MH /QD75MH /
LD77MH
Command resolution
Linear encoder resolution unit
Amplifier setting
MR-J3-B Linear
MR-J3-B Linear
Motor setting
Automatic setting
No.
(Note 1)
Symbol
Name
Factory
setting
PA01 **STY Control mode (Note 2)
0000h
0004h
0004h
PC01 ERZ Error excessive alarm level
100
PC03 *ENRS Encoder output pulse selection
0010h
PC26 **COP8 Function selection C-8
0100h
PC27 **COP9 Function selection C-9
0000h
PS01 **LIT1 Linear function selection 1
0301h
PS02 **LIM Linear encoder resolution setting
Numerator
1000
PS03 **LID Linear encoder resolution setting
Denominator
1000
PS04 *LIT2 Linear function selection 2
0003h
PS05 LB1
Linear servo motor control position deviation
error detection level
0
PS06 LB2
Linear servo motor control speed deviation
error detection level
0
PS07 LB3
Linear servo motor control thrust deviation
error detection level
100
PS08 *LIT3 Linear function selection 3
0010h
PS09 LPWM Magnetic pole detection voltage level
30
PS10 LFH
At magnetic pole detection current detection
method Identification signal frequency
5
PS11 LIDH At magnetic pole detection current detection
method Identification signal amplitude
100
PS12
This parameter is not used. (Note 2)
500
PS17 LTSTS Minute position detection method function
selection Each
0000h
Servo
parameters
PS18 IDLV Minute position detection method
identification signal amplitude
0000h
Set as necessary.
Set as necessary.
Unit setting
mm
mm
Parameter
for
positioning
control
Number of pulses (AP)
Travel distance (AL)
Refer to (2) (b) in this section.
Note 1. The parameter whose symbol preceded by * can be validated with the following conditions.
* : Turn off the power and then on again, or reset the controller after setting the parameter.
**: Turn off the power and then on again after setting the parameter.
2. For the QD75 MH , make sure to set the factory setting.
3. GX Configurator-QP(SW2D5C-QD75P) of Ver.2.29F or later supports the MR-J3- B linear.
4. Note that the following.
When a servo amplifier parameter (servo parameter) is changed, the controller automatically reads the servo parameter and
stores the new servo parameter in the buffer memory of the QD74MH , QD75MH or LD77MH. However, the new servo
parameter is not reflected in the flash memory.
Right after the servo parameter is changed, if the QD74MH , QD75MH or LD77MH is turned off or reset, or if the control circuit
power supply of the servo amplifier is turned off, the new servo parameter may not be reflected in the buffer memory. In this case,
change the servo parameter again.
Содержание MELSERVO-J3W Series
Страница 17: ...8 MEMO ...
Страница 27: ...1 FUNCTIONS AND CONFIGURATION 1 10 MEMO ...
Страница 87: ...4 STARTUP 4 14 MEMO ...
Страница 117: ...5 PARAMETERS 5 30 MEMO ...
Страница 129: ...6 GENERAL GAIN ADJUSTMENT 6 12 MEMO ...
Страница 185: ...10 CHARACTERISTICS 10 8 MEMO ...
Страница 241: ...11 OPTIONS AND AUXILIARY EQUIPMENT 11 56 MEMO ...
Страница 274: ...13 USING A LINEAR SERVO MOTOR 13 25 1 2 3 4 ...