background image

LINUS Live v.1.2.0 Beta

2017_01_20

1

LINUS System

Quickstart 

Содержание LINUS System

Страница 1: ...LINUS Live v 1 2 0 Beta 2017_01_20 1 LINUS System Quickstart ...

Страница 2: ...E T AES3 OVER ETHERNET PRIM SEC IN OUT DAN ETHERNET L I N E T POWER ON OFF ON OFF 2 3 1 PUSH 3 2 1 PUSH 3 2 1 2 3 1 1 Verify Master Slave configuration in LINUS Rack 20 40 Start the Rack configuration before any frontpanel connected cables Master Slave Master Slave Master Slave Linus10 Master 03 P 14 ViRAY A I 1_LF 1_HF G 0 0 0 0 Linus10 Slave 03 P 14 ViRAY A I 1_LF 1_HF G 0 0 0 0 ...

Страница 3: ...ollows follows After selecting the Module Number on the Master unit and entered the command the Master Unit starts a device scan and ends with a message Device Found 1 this is the Slave unit The Slave unit will automatically follow the Master unit Doublecheck the IP adress on the last page on the units displays Module No 1 example Master xxx xxx xx 01 Slave xxx xxx xx 02 Module No 2 example Master...

Страница 4: ...ernet cables PRIM SEC Example shows Daisy Chain Topology other Network topologies possible PAN 8 INPUT A LINK A INPUT B LINK B PRIM SEC IN OUT DAN ETHERNET L I N E T 2 3 1 PUSH 3 2 1 PUSH 3 2 1 2 3 1 LINUS Rack 20 LINUS Rack 40 Set Static IP IP 192 168 1 20 SN 255 255 0 0 ...

Страница 5: ...ar indication of available units in the network If the Scan result do not match with your hardware check the setup of devices and network mentioned previously Master Module Number 1 IP xxx xx xx 01 Slave IP xxx xx xx 02 Example shows the initial connection of devices LINUS Live includes a new FirmWare Version ...

Страница 6: ...and Press The Device Scan process window informs you about a new in Linus Live implemented FirmWare for the scanned devices You now need to upload the FirmWare of the connected devices Press Add to include all modules into the setup space Step 2 on next page ...

Страница 7: ...e same type Press Firmware and Upload Firmware Wait until the Firmware Upload is completed LINUS Live will close and LINUS 10 will reboot automatically after the Firmware update has been completed Note Do not update more than 8x LINUS10 Units at any one time 1 2 ...

Страница 8: ...ess The Device Scan process window informs you about a new in Linus Live implemented Preset Library for the scanned devices You now need to upload the Preset Library of the connected Devices Press Add to include all modules into the setup space Step 4 on next page ...

Страница 9: ...p 4 Library Update Select all modules from the same type Press Library and Upload Library Wait until the Library Upload is completed LINUS Live will close automatically after the Library Update has been completed 1 2 ...

Страница 10: ...d Environment Start LINUS Live and Press The Device Scan process window informs you about an updated Device environment You can start now with LINUS Live operation Please refer to the LINUS Startup manual for further information ...

Страница 11: ...eset Library on all the devices in your system setup The Device Scan process window informs you that the detected devices in the network have got a Mixed User Library You now need to upload the Preset Library of the connected Devices Press Add to include all modules into the setup space Please reffer to Page 9 You will find further information for the Preset Builder application in the Preset Build...

Страница 12: ... the Modules System Setup Files and LINUS Live operate on the same Key file Note We recommend to design the required user default preset combinationsfor all kinds of Units LINUS10 LINUS 10C LINUS 5C LINUS Con in one go and upload the Library on the units The Key Files are located in the following directories Win C Users xxx LINUS Presets Mac Users xxx LINUS Presets Export Copy Paste the generated ...

Страница 13: ...nline and have not changed any parameters or system configuration you can restore the system at anytime on the same computer e g if network has failed or in the case of power shut down Start LINUS Live and Press If the preconfigured configuration hasn t been changed you can restore the System setup ...

Страница 14: ...rt the used preset Lib Key from the original computer where the system setup has been created Please refer to Page 12 Import function IMPORTANT Restart LINUS Live Software after Key File import Start LINUS Live and Press Now you will be able to restore the system setup on a different computer ...

Страница 15: ...SENSOR 5 6 SENSOR 7 8 OUT 3 4 L I N E T AES3 OVER ETHERNET PRIM SEC IN OUT DAN ETHERNET L I N E T POWER ON OFF ON OFF 2 3 1 PUSH 3 2 1 PUSH 3 2 1 2 3 1 Key 1 Key 1 PAN 8 INPUT A LINK A INPUT B LINK B 1 AMP 1 A 2 AMP 1 B SENSOR 1 2 SENSOR 3 4 1 AMP 2 A 2 AMP 2 B OUT 1 OUT 1 2 OUT 2 OUT 3 OUT 4 SENSOR 5 6 SENSOR 7 8 OUT 3 4 L I N E T AES3 OVER ETHERNET PRIM SEC IN OUT DAN ETHERNET L I N E T POWER ON...

Отзывы: