15 - 10
15. COMMUNICATION FUNCTION
15.4 Command and data No. list
POINT
If the command and data No. are the same, the description may be different
depending on models of servo amplifiers.
15.4.1 Read commands
(1) Status display (Command [0][1])
Command
Data No.
Description
Display item
Frame length
[0] [1]
[0] [0]
Status display name and unit
Current position
16
[0] [1]
Command position
[0] [2]
Command remaining distance
[0] [3]
Point table No.
[0] [4]
Cumulative feedback pulses
[0] [5]
Servo motor speed
[0] [6]
Droop pulses
[0] [7]
[0] [8]
[0] [9]
[0] [A]
Regenerative load ratio
[0] [B]
Effective load ratio
[0] [C]
Peak load ratio
[0] [D]
Instantaneous torque
[0] [E]
Position within one-revolution
[0] [F]
ABS counter
[1] [0]
Load inertia moment ratio
[1] [1]
Bus voltage
[8] [0]
Status display data value and
processing information
Current position
12
[8] [1]
Command position
[8] [2]
Command remaining distance
[8] [3]
Point table No.
[8] [4]
Cumulative feedback pulses
[8] [5]
Servo motor speed
[8] [6]
Droop pulses
[8] [7]
[8] [8]
[8] [9]
[8] [A]
Regenerative load ratio
[8] [B]
Effective load ratio
[8] [C]
Peak load ratio
[8] [D]
Instantaneous torque
[8] [E]
Position within one-revolution
[8] [F]
ABS counter
[9] [0]
Load inertia moment ratio
[9] [1]
Bus voltage
Содержание Melservo-J3 Series MR-J3-B
Страница 19: ...10 MEMO ...
Страница 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Страница 61: ...2 6 2 INSTALLATION MEMO ...
Страница 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Страница 241: ...5 62 5 OPERATION MEMO ...
Страница 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Страница 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Страница 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Страница 793: ...App 38 APPENDIX MEMO ...
Страница 799: ...MEMO ...