17 - 22
17. SPEED CONTROL OPERATION
17.3 Signal
17.3.1 Signal (device) explanations
POINT
In the case of speed control operation, the devices assigned to the CN6
connector cannot be changed.
(1) I/O device
(a) Input device
POINT
Devices that are assigned to the CN6 connector cannot be used with the
RY of CC-Link.
Device
Device
Symbol
Connector
Pin No.
Functions/Applications
Forced stop
EMG
CN6-1
When EMG is turned off, the servo motor will be stopped forcibly. At this time, the
servo turns off, and the dynamic brake operates to stop the servo motor
immediately.
The forced stop will be reset when EMG is turned on.
Forward rotation stroke end
LSP
CN6-3
For the details of the devices, refer to section 17.2.2 (1).
Reverse rotation stroke end
LSN
CN6-4
(b) Output device
POINT
The output devices assigned to the CN6 connector pins can be used for
CC-Link RX.
Device
Device
Symbol
Connector
Pin No.
Functions/Applications
Ready
RD
CN6-14 For the details of the device, refer to section 17.2.2 (2).
Malfunction
ALM
CN6-15 ALM turns off when the power is switched off or the protective circuit is activated to
shut off the base circuit. When no alarm occurs, ALM turns on in about 1.5 s after
power-on.
The logic of RX (n+1) A or RX (n+3)A) is reversed.
(2) Input signal
Signal name
Signal
Symbol
Connector
Pin No.
Functions/Applications
Manual pulse generator
PP
CN6-6
Not used in speed control operation.
NP
CN6-19
Содержание Melservo-J3 Series MR-J3-B
Страница 19: ...10 MEMO ...
Страница 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Страница 61: ...2 6 2 INSTALLATION MEMO ...
Страница 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Страница 241: ...5 62 5 OPERATION MEMO ...
Страница 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Страница 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Страница 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Страница 793: ...App 38 APPENDIX MEMO ...
Страница 799: ...MEMO ...