5 - 43
5. OPERATION
(2) Timing chart
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Rough match (RXn2)
Servo motor speed
Forward rotation start (RYn1)
Home position return speed
Creep speed
Moving distance after proximity dog
Home position shift distance
6ms or more
3ms or less
Selected point table No.
Forward
rotation
0r/min
0
4ms or more (Note)
Movement completion (RXnC)
Home position return
completion (RXn3/ZP)
Automatic/manual selection
(RYn6)
Proximity dog (DOG)
Proximity dog
Reverse rotation start (RYn2)
Home position address
parameter No.PC07
Note. Configure a sequence that changes the point table selection earlier, considering the delay time of CC-Link communication.
The parameter No.PC17 (home position return position data) setting value is the positioning address after