16 - 80
16. INDEXER POSITIONING OPERATION
(b) Auto tuning response (parameter No.PA09)
If the machine hunts or generates large gear sound, decrease the set value. To improve performance,
e.g. shorten the settling time, increase the set value.
Setting Response
Guideline for machine
resonance frequency [Hz]
Setting Response
Guideline for machine
resonance frequency [Hz]
1
Low response
10.0
17
Low response
67.1
2
11.3
18
75.6
3 12.7
19 85.2
4 14.3
20 95.9
5 16.1
21 108.0
6 18.1
22 121.7
7 20.4
23 137.1
8 23.0
24 154.4
9 25.9
25 173.9
10 29.2
26 195.9
11 32.9
27 220.6
12 37.0
28 248.5
13 41.7
29 279.9
14 47.0
30 315.3
15 52.9
31 355.1
16 Middle
response
59.6
32 Middle
response
400.0
(9) In-position range
Parameter
Initial
value
Unit Setting
range
No. Symbol
Name
PA10
INP
In-position range
100
pulse
0 to 10000
Set the range for outputting travel completion (RXnC) and in-position (RXn1) in command pulse unit.
Servo motor Droop pulse
In-position range [pulse]
Command pulse
Command pulse
Droop pulse
In position (RXn1)
ON
OFF
Содержание Melservo-J3 Series MR-J3-B
Страница 19: ...10 MEMO ...
Страница 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Страница 61: ...2 6 2 INSTALLATION MEMO ...
Страница 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Страница 241: ...5 62 5 OPERATION MEMO ...
Страница 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Страница 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Страница 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Страница 793: ...App 38 APPENDIX MEMO ...
Страница 799: ...MEMO ...