16 - 5
16. INDEXER POSITIONING OPERATION
Programmable controller
Servo amplifier (RWwn)
Servo amplifier
Programmable controller (RWrn)
(Note 1)
Address No.
Signal
(Note 1)
Address No.
Signal
RWwn
Monitor 1 (Note 2)
RWrn
Monitor 1 data lower 16 bit
RWwn
1 Monitor 2 (Note 2)
RWwn
1 Monitor 1 data upper 16 bit
RWwn
2 Instruction
code
RWwn
2 Respond
code
RWwn
3 Writing
data
RWwn
3 Reading
data
RWwn
4 Next
station
RWwn
4 Not
available
RWwn
5 Not
available
RWwn
5 Monitor 2 data lower 16 bit
RWwn
6 Point table No./Speed command data (Note 3)
RWwn
6 Monitor 2 data upper 16 bit
RWwn
7 Not
available
RWwn
7 Not
available
Note 1. "n" depends on the station number setting.
2. Specify the code of the lower 16 bit as the monitor code of 32-bit data.
3. When the parameter No.PC30 setting is "
0 ", specify the point table No. in RWwn 6. When the parameter No.PC30
setting is "
1 ", specify the speed data in RWwn 6, and turn ON Speed command execution demand (RY(n 2)1). When
setting the parameter No.PC30 to "
1 ", always set the acceleration/deceleration time constant in the point table No.1.
16.2.2 Detailed explanation of I/O signals
(1) Input signals (Input devices)
The note signs in the remarks column indicate the following descriptions.
*: Can be automatic turned ON internally by setting parameters No.PD01.
Signal name
(Device name)
Description
Device No.
Remarks
1 station
occupied
2 stations
occupied
Servo-on
Turning RYn0 ON powers on the base circuit, making
operation ready to start. (Servo on status)
Turning it OFF powers off the base circuit, coasting the servo
motor. (Servo off status)
RYn0 RYn0 *
Start
1. Automatic operation mode 1 and 2
Turning on RYn1 performs positioning operation once to the
specified station number.
2. Manual operation mode
Turning on RYn1 in the indexer JOG operation makes the
servo motor rotate in the RYn2 specified direction only while
RYn1 is on. Turning it off makes the servo motor perform
positioning to the station where the servo motor can
decelerate to stop.
Turning on RYn1 in JOG operation makes the servo motor
rotate in the RYn2 specified direction only while RYn1 is on.
Turning it off makes the servo motor decelerate to stop
regardless of stations.
3. Home position return mode
Turning on RYn1 immediately starts a home position return.
RYn1 RYn1
Содержание Melservo-J3 Series MR-J3-B
Страница 19: ...10 MEMO ...
Страница 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Страница 61: ...2 6 2 INSTALLATION MEMO ...
Страница 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Страница 241: ...5 62 5 OPERATION MEMO ...
Страница 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Страница 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Страница 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Страница 793: ...App 38 APPENDIX MEMO ...
Страница 799: ...MEMO ...