A - 4
CAUTION
When you keep or use the equipment, please fulfill the following environmental conditions.
Item
Environment
Servo amplifier
Servo motor
Ambient
temperature
In operation
[ ] 0
to 55 (non-freezing)
0 to 40 (non-freezing)
[ ]
32 to 131 (non-freezing)
32 to 104 (non-freezing)
In storage
[ ]
20 to 65 (non-freezing)
15 to 70 (non-freezing)
[ ]
4 to 149 (non-freezing)
5 to 158 (non-freezing)
Ambient
humidity
In operation
90%RH or less (non-condensing)
80%RH or less (non-condensing)
In storage
90%RH or less (non-condensing)
Ambience
Indoors (no direct sunlight) Free from corrosive gas, flammable gas, oil mist, dust and dirt
Altitude
Max. 1000m (3280 ft) above sea level
(Note)
Vibration
resistance
[m/s
2
]
5.9 m/s
2
, 10 to 55Hz
(directions of X, Y
and Z axes)
HF-MP series
HF-KP series
X Y: 49
HF-SP51 81 HF-SP52
to
152
HF-SP524 to 1524
HC-RP Series HC-UP72 152
HF-JP53 to 503 11K1M 15K1M
HF-JP534 to 5034 11K1M4 15K1M4
X Y: 24.5
HF-SP121 201 HF-SP202 352
HF-SP2024 3524 HC-UP202
to
502
X: 24.5 Y: 49
HF-SP301 421 HF-SP502 702
HF-SP5024 7024 HF-JP703 903
HF-JP7034 9034
X: 24.5 Y: 29.4
HC-LP52 to 152
X: 9.8 Y: 24.5
HC-LP202 to 302
X: 19.6 Y: 49
HA-LP601 to 12K1
HA-LP701M to 15K1M
HA-LP502 to 22K2
HA-LP6014 12K14
HA-LP701M4 15K1M4 HA-LP11K24
to
22K24
X: 11.7 Y: 29.4
HA-LP15K1 to 25K1
HA-LP22K1M
HA-LP15K14 20K14 HA-LP22K1M4
X Y: 9.8
Note. Except the servo motor with a reduction gear.
The servo amplifier must be installed in a metal control box.
When fumigants that contain halogen materials, such as fluorine, chlorine, bromine, and iodine, are used
for disinfecting and protecting wooden packaging from insects, they cause malfunction when entering our
products. Please take necessary precautions to ensure that remaining materials from fumigant do not
enter our products, or treat packaging with methods other than fumigation, such as heat treatment.
Additionally, disinfect and protect wood from insects before packing the products.
Содержание Melservo-J3 Series MR-J3-B
Страница 19: ...10 MEMO ...
Страница 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Страница 61: ...2 6 2 INSTALLATION MEMO ...
Страница 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Страница 241: ...5 62 5 OPERATION MEMO ...
Страница 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Страница 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Страница 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Страница 793: ...App 38 APPENDIX MEMO ...
Страница 799: ...MEMO ...