16 - 9
16. INDEXER POSITIONING OPERATION
Signal name
(Device name)
Description
Device No.
Remarks
1 station
occupied
2 stations
occupied
Speed selection 1
Set the servo motor speed, acceleration time constant, and
deceleration time constant for positioning operation by
selecting the point table number from 1 to 8 using RY(n 2)C,
RY(n 2)D, and RY(n 2)E.
RY(n 2)C
Speed selection 2
RY(n 2)D
Speed selection 3
RY(n 2)E
(Note) RY of CC-Link
Point table No.
RY(n 2)E RY(n 2)D RY(n 2)C
0
0
0
1
0
0
1
2
0
1
0
3
0
1
1
4
1
0
0
5
1
0
1
6
1
1
0
7
1
1
1
8
Note.
0:
OFF
1: ON
Reset Keeping
RY(n 1)A or RY(n 3)A ON for 50ms or longer
allows an alarm to be deactivated.
Some alarms cannot be deactivated by Reset RY(n 1)A or
RY(n 3)A. (Refer to section 16.12.4 (1))
If RY(n 1)A or RY(n 3)A is turned ON with no alarm
occurring, the base circuit will not be shut off. When "
1 "
is set in parameter No.PD20 (function selection D-1), the base
circuit is shut off.
This device is not designed to make a stop. Do not turn it ON
during operation.
RY(n 1)A RY(n 3)A
Содержание Melservo-J3 Series MR-J3-B
Страница 19: ...10 MEMO ...
Страница 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Страница 61: ...2 6 2 INSTALLATION MEMO ...
Страница 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Страница 241: ...5 62 5 OPERATION MEMO ...
Страница 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Страница 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Страница 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Страница 793: ...App 38 APPENDIX MEMO ...
Страница 799: ...MEMO ...