10 - 7
10. SPECIAL ADJUSTMENT FUNCTIONS
(3) Vibration suppression control tuning procedure
No
Vibration suppression control tuning
Operation
Is the target response
reached?
Execute or re-execute vibration
suppression control tuning. (Set
parameter No.PB02 to " 1".)
Decrease the response until vibration
of workpiece end/device is resolved.
End
Yes
No
No
Yes
Increase the response setting.
Has vibration of workpiece
end/device increased?
Has vibration of workpiece
end/device been resolved?
Using the machine analyzer or from
machine side vibration waveform,
set the vibration suppression control
manually.
Factor
Estimation cannot be made as
machine side vibration has not been
transmitted to the motor side.
The response of the model loop gain
has increased to the machine side
vibration frequency (vibration
suppression control limit).
Yes
Tuning ends automatically after
positioning operation is performed
the predetermined number of times.
(Parameter No. PB02 is changed to
" 2" or " 0".)
Stop operation.
Resume operation.
Содержание Melservo-J3 Series MR-J3-B
Страница 19: ...10 MEMO ...
Страница 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Страница 61: ...2 6 2 INSTALLATION MEMO ...
Страница 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Страница 241: ...5 62 5 OPERATION MEMO ...
Страница 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Страница 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Страница 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Страница 793: ...App 38 APPENDIX MEMO ...
Страница 799: ...MEMO ...