16 - 3
16. INDEXER POSITIONING OPERATION
Function Description
Reference
Alarm history clear
Alarm history is cleared.
Parameter No.
PC18
Torque limit
Servo motor-torque is limited.
Section 16.3.2 (3)
Section 16.11.1 (9)
Output signal (DO) forced output
Output signal can be forced on/off independently of the servo status.
Use this function for output signal wiring check, etc.
Section 7.7.4
Section 8.5.7(4)
Test operation mode
JOG operation positioning operation DO forced output.
MR Configurator is necessary for this function.
Section 7.7
Section 8.5.7
Limit switch
The servo motor travel region can be limited using the forward rotation
stroke end (LSP)/reverse rotation stroke end (LSN).
16.2 I/O signals (I/O devices) transferred to/from the programmable controller CPU
16.2.1 I/O signals (I/O devices)
(1) When 1 station is occupied
RYn/RXn: 32 points each, RWrn/RWwn: 4 points each
Programmable controller
Servo amplifier (RYn)
Servo amplifier
Programmable controller (RXn)
(Note)
Device No.
Device name
(Note)
Device No.
Device name
RYn0 Servo-on
RXn0 Ready
RYn1 Start
RXn1 In
position
RYn2 Rotation
direction
specifying
RXn2 Rough
match
RYn3
RXn3
Home position return completion
to
Not available
RXn4
Limiting torque
RYn5
RXn5 Not
available
RYn6
Operation mode selection 1
RXn6
Electromagnetic brake interlock
RYn7
Operation mode selection 2
RXn7
Not available
RYn8
Monitor output execution demand
RXn8
Monitoring
RYn9
Instruction code execution demand
RXn9
Instruction code execution completion
RYnA
Next station selection 1
RXnA
Warning
RYnB
Next station selection 2
RXnB
Battery warning
RYnC
Next station selection 3
RXnC
Movement completion
RYnD
Next station selection 4
RXnD
Dynamic brake interlock
RYnE
Next station selection 5
RXnE
RYnF
to Not
available
to Not
available
RX(n
1)9
RY(n
1)9
RX(n
1)A Trouble
RY(n
1)A Reset
RX(n
1)B Remote station communication ready
RY(n
1)B
RX(n
1)C
to Not
available
to Not
available
RY(n
1)F
RX(n
1)F
Programmable controller
Servo amplifier (RWwn)
Servo amplifier
Programmable controller (RWrn)
Address No.
Signal
Address No.
Signal
RWwn
Monitor 1
RWrn
Monitor 1 data
RWwn
1 Monitor
2
RWrn
1 Monitor
2
data
RWwn
2 Instruction
code
RWrn
2 Respond
code
RWwn
3 Writing
data
RWrn
3 Reading
data
Note. "n" depends on the station number setting.
Содержание Melservo-J3 Series MR-J3-B
Страница 19: ...10 MEMO ...
Страница 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Страница 61: ...2 6 2 INSTALLATION MEMO ...
Страница 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Страница 241: ...5 62 5 OPERATION MEMO ...
Страница 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Страница 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Страница 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Страница 793: ...App 38 APPENDIX MEMO ...
Страница 799: ...MEMO ...