14 - 48
14. OPTIONS AND AUXILIARY EQUIPMENT
(3) Precautions for wiring
The cables between the servo amplifier and the brake unit, and between the resistor unit and the brake unit
should be as short as possible. Always twist the cable longer than 5m (twist five times or more per one
meter). Even when the cable is twisted, the cable should be less than 10m. Using cables longer than 5m
without twisting or twisted cables longer than 10m, may result in the brake unit malfunction.
Servo amplifier
Brake unit
5m or less
5m or less
Servo amplifier
Brake unit
10m or less
10m or less
P( )
N( )
P
N
P
PR
PR
P
N
P
PR
P
PR
Twist
Resistor unit
Resistor unit
P( )
N( )
Twist
P
(4) Cables
(a) Cables for the brake unit
For the brake unit, HIV wire (600V Grade heat-resistant polyvinyl chloride insulated wire) is
recommended.
1) Main circuit terminal
Brake unit
Main
circuit
terminal
screw
size
Crimping
terminal
Tightening
torque
[N m]
([Ib in])
Wire size
N/ , P/ , PR,
N/
P/
PR
Terminal block
N/ , P/ ,
PR,
HIV wire [mm
2
] AWG
200V FR-BU2-15K
M4
5.5-4
1.5(13.3)
3.5
12
class FR-BU2-30K
M5
5.5-5
2.5(22.1)
5.5
10
FR-BU2-55K
M6
14-6 4.4(38.9)
14
6
400V FR-BU2-H30K
M4
5.5-4
1.5(13.3)
3.5
12
class FR-BU2-H55K
M5
5.5-5
2.5(22.1)
5.5
10
FR-BU2-H75K M6
14-6 4.4(38.9)
14
6
Содержание Melservo-J3 Series MR-J3-B
Страница 19: ...10 MEMO ...
Страница 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Страница 61: ...2 6 2 INSTALLATION MEMO ...
Страница 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Страница 241: ...5 62 5 OPERATION MEMO ...
Страница 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Страница 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Страница 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Страница 793: ...App 38 APPENDIX MEMO ...
Страница 799: ...MEMO ...