3 - 11
3. CC-LINK COMMUNICATION FUNCTIONS
Programmable controller
Servo amplifier (RWwn)
Servo amplifier
Programmable controller (RWrn)
(Note 1)
Address No.
Signal name
(Note
1)
Address No.
Signal name
RWwn
(Note 2) Monitor 1
RWrn
Monitor 1 data lower 16 bit
RWwn
1 (Note 2) Monitor 2
RWwn
1 Monitor 1 data upper 16 bit
RWwn
2 Instruction
code
RWwn
2 Respond
code
RWwn
3 Writing
data
RWwn
3 Reading
data
RWwn
4 (Note 3) Position command data lower 16 bit/Point table No.
RWwn
4 Reserved
RWwn
5 Position command data upper 16 bit
RWwn
5 Monitor 2 data lower 16 bit
RWwn
6 (Note 4) Speed command data/Point table No.
RWwn
6 Monitor 2 data upper 16 bit
RWwn
7 Reserved
RWwn
7 Reserved
Note 1. "n" depends on the station number setting.
2. Specify the code of the lower 16 bit as the monitor code of 32-bit data.
3. When the parameter No.PC30 setting is "
0", specify the point table No. in RWwn 4. When the parameter No.PC30
setting is "
1" or "
2", specify the position data in RWwn 4/RWwn 5 and turn ON Position command execution
demand (RY(n 2)0).
4. When the parameter No.PC30 setting is "
1", specify the point table No. in RWwn 6. When the parameter No.PC30
setting is "
2", specify the speed data in RWwn 6, and turn ON Speed command execution demand (RY(n 2)1). When
setting the parameter No.PC30 to "
2", always set the acceleration/deceleration time constant in the point table No.1.
When the parameter No.PC30 setting is "
0", the RWwn 6 value is not used.
Содержание Melservo-J3 Series MR-J3-B
Страница 19: ...10 MEMO ...
Страница 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Страница 61: ...2 6 2 INSTALLATION MEMO ...
Страница 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Страница 241: ...5 62 5 OPERATION MEMO ...
Страница 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Страница 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Страница 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Страница 793: ...App 38 APPENDIX MEMO ...
Страница 799: ...MEMO ...