16 - 25
16. INDEXER POSITIONING OPERATION
16.3.2 Detailed description of signals (devices)
(1) Forward rotation start reverse rotation start temporary stop/restart
(a) A start (RYn1) should make the sequence which can be used after the main circuit has been
established. These signals are invalid if it is switched on before the main circuit is established.
Normally, it is interlocked with the ready signal (RD).
(b) A start in the servo amplifier is made when a start (RYn1) changes from OFF to ON. The delay time of
the servo amplifier's internal processing is max. 3ms. The delay time of other devices is max. 10ms.
(c) When a programmable controller is used, the ON time of a start (RYn1), should be 6ms or longer to
prevent a malfunction.
(d) During operation, the start (RYn1) is not accepted. The next operation should always be started after
the rough match (RXn2) is output with the rough match output range set to “0” or after the movement
completion (RXnC) is output.