Use the UL/cUL standard-compliant products.
Use the molded-case circuit breaker (UL489 Listed MCCB) or a Class T fuse indicated in the table below.
Servo amplifier
Molded-case circuit breaker (Note)
Fuse
Current
Voltage AC [V]
Current [A]
Voltage AC [V]
MR-J3-10T(1) 20T
50A frame 5A
10
MR-J3-40T 20T1
50A frame 10A
15
MR-J3-60T to 100T 40T1
50A frame 15A
20
MR-J3-200TN
50A frame 20A
40
MR-J3-350T
50A frame 30A
240
70
300
MR-J3-500T
50A frame 50A
125
MR-J3-700T
100A frame 75A
150
MR-J3-11KT
100A frame 100A
200
MR-J3-15KT
225A frame 125A
250
MR-J3-22KT
225A frame 175A
350
MR-J3-60T4
50A frame 5A
10
MR-J3-100T4
50A frame 10A
15
MR-J3-200T4
50A frame 15A
25
MR-J3-350T4
50A frame 20A
35
MR-J3-500T4
50A frame 30A
600Y/347
50
600
MR-J3-700T4
50A frame 40A
65
MR-J3-11KT4
60A frame 60A
100
MR-J3-15KT4
100A frame 7A
150
MR-J3-22KT4
225A frame 125A
175
Note. Listed molded-case circuit breakers are for when the power factor improving reactor is not used.
(11) Configuration diagram
Representative configuration diagram example to conform to the UL/cUL standard is shown below. The
grounding wiring is excluded from the figure configuration.
Power supply
CN1
CN2
Controller
Encoder cable
Control box side
Machine side
Servo motor
Encoder
Servo amplifier
L
1
, L
2
, L
3
L
11
, L
21
U, V, W
Fuse or
Molded-case
circuit breaker
Содержание Melservo-J3 Series MR-J3-B
Страница 19: ...10 MEMO ...
Страница 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Страница 61: ...2 6 2 INSTALLATION MEMO ...
Страница 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Страница 241: ...5 62 5 OPERATION MEMO ...
Страница 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Страница 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Страница 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Страница 793: ...App 38 APPENDIX MEMO ...
Страница 799: ...MEMO ...