17 - 40
17. SPEED CONTROL OPERATION
(6) Auto tuning
Parameter
Initial value
Unit
Setting range
No. Symbol
Name
PA08
ATU
Auto tuning mode
0001h
Refer to the text.
PA09
RSP
Auto tuning response
12
1 to 32
Make gain adjustment using auto tuning. Refer to section 9.2 for details.
(a) Auto tuning mode (parameter No.PA08)
Select the gain adjustment mode.
0 0 0
0
1
2
3
Parameter No.PA08
Gain adjustment mode setting
Setting Gain adjustment mode Automatically set parameter No. (Note)
Interpolation mode
Auto tuning mode 1
Auto tuning mode 2
Manual mode
PB06 PB08 PB09 PB10
PB06 PB07 PB08 PB09 PB10
PB07 PB08 PB09 PB10
Note. The parameters have the following names.
Parameter No.
Name
PB06
Load to motor inertia ratio
PB07
Model loop gain
PB08
Position loop gain
PB09
Speed loop gain
PB10
Speed integral compensation