14 - 88
14. OPTIONS AND AUXILIARY EQUIPMENT
(c) Cable clamp fitting AERSBAN - SET
Generally, the grounding of the shielded wire may only be connected to the connector's SD terminal.
However, the effect can be increased by directly connecting the cable to a ground plate as shown below.
Install the ground plate near the servo amplifier for the encoder cable. Peel part of the cable sheath to
expose the external conductor, and press that part against the ground plate with the cable clamp. If the
cable is thin, clamp several cables in a bunch.
The clamp comes as a set with the ground plate.
[Unit: mm]
4
0
Cable clamp
(A, B)
Cable
Ground plate
cutter
cable
Strip the cable sheath of
the clamped area.
External conductor
Clamp section diagram
Outline drawing
[Unit: mm]
3
7
C A
6
6
Ground plate
2- 5 hole
mounting hole
17.5
24
0 -0
.2
B ± 0
.3
(Note) M4 screw
35
35
22
11
[Unit: mm]
30
10
24
+0.
3
0
Clamp Section diagram
L or less
Note. Screw hole for grounding. Connect it to the ground plate of the control box.
Type
A
B
C
Accessory fittings
Clamp fitting
L
AERSBAN-DSET
100
86
30
Clamp A: 2pcs.
A
70
AERSBAN-ESET
70
56
Clamp B: 1pc.
B
45
Содержание Melservo-J3 Series MR-J3-B
Страница 19: ...10 MEMO ...
Страница 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Страница 61: ...2 6 2 INSTALLATION MEMO ...
Страница 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Страница 241: ...5 62 5 OPERATION MEMO ...
Страница 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Страница 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Страница 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Страница 793: ...App 38 APPENDIX MEMO ...
Страница 799: ...MEMO ...